Open-tubular capillary electrochromatography using a polymeric surfactant coating

被引:36
作者
Kamande, MW [1 ]
Kapnissi, CP [1 ]
Zhu, XF [1 ]
Akbay, C [1 ]
Warner, IM [1 ]
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
关键词
benzodiazepine; open-tubular capillary electrochromatography phenol; polymeric surfactant;
D O I
10.1002/elps.200390137
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A stable polyelectrolyte multilayer (PEM) coating was investigated for use in open-tubular capillary electrochromatography (o-CEC). In this approach, the PEM consisted of the cationic polymer of a quaternary ammonium salt, poly(diallyldimethylammonium chloride) and the anionic polymeric surfactant, poly(sodium undecylenic sulfate). Both the cationic and anionic polymers were physically adsorbed to the surface of a fused-silica capillary by use of a simple coating procedure. This procedure involved an alternate rinse of the positively and negatively charged polymers. The performance of the PEM coating as a dynamic stationary phase was evaluated by use of electrochromatographic experiments and showed good selectivity for both phenols and benzodiazepines. Reproducibility of the PEM coating was also evaluated by calculating the relative standard deviations (RSDs) of the electroosomotic flow (EOF). The run-to-run and capillary-to-capillary RSD values of the EOF were less than 1.5%. The endurance of the coating was more than 100 runs. The importance of the PEM coating was illustrated by comparing separations on a bare uncoated capillary with the coated capillary. In addition, the chromatographic performance using o-CEC and micellar electrokinetic chromatography (MEKC) was compared for the separation of benzodiazepines.
引用
收藏
页码:945 / 951
页数:7
相关论文
共 56 条
[1]  
Akbay C, 1999, ELECTROPHORESIS, V20, P145, DOI 10.1002/(SICI)1522-2683(19990101)20:1<145::AID-ELPS145>3.3.CO
[2]  
2-U
[3]   Characterization of surfactant coatings in capillary electrophoresis by atomic force microscopy [J].
Baryla, NE ;
Melanson, JE ;
McDermott, MT ;
Lucy, CA .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :4558-4565
[4]  
Bedair M, 2002, ELECTROPHORESIS, V23, P2938, DOI 10.1002/1522-2683(200209)23:17<2938::AID-ELPS2938>3.0.CO
[5]  
2-8
[6]  
Bendahl L, 2001, ELECTROPHORESIS, V22, P2565, DOI 10.1002/1522-2683(200107)22:12<2565::AID-ELPS2565>3.0.CO
[7]  
2-I
[8]  
Chiari M, 2001, ELECTROPHORESIS, V22, P656, DOI 10.1002/1522-2683(200102)22:4<656::AID-ELPS656>3.0.CO
[9]  
2-S
[10]   Characterization of poly(dimethylacrylamide) and the combination of poly(vinyl alcohol) and cetyltrimethylanlmonium bromide as dynamic electroosmotic flow suppression agents in capillary electrophoresis [J].
Chiari, M ;
Damin, F ;
Reijenga, JC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :15-23