Effect of oxovanadium(IV) acetylacetonate on the chemiluminescence reaction of luminol in reverse micelles.

被引:19
作者
Fujiwara, T [1 ]
Kyaw, T [1 ]
Okamoto, Y [1 ]
Kumamaru, T [1 ]
机构
[1] Hiroshima Univ, Fac Sci, Dept Chem, Higashihiroshima 739, Japan
关键词
chemiluminescence; luminol; oxovanadium(IV) acetylacetonate; reverse micelles; cetyltrimethylammonium chloride;
D O I
10.2116/analsci.13.Supplement_59
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Upon mixing of oxovanadium(IV) acetylacetonate, this complex caused an increase in the chemiluminescence (CL) of luminol in a reverse micellar medium of cetyltrimethylammonium chloride in chloroform-cyclohexane (6:5 v/v)-water (buffered with NaOH-Na2CO3, pH 12.5) even in the absence of an oxidizing reagent such as hydrogen peroxide. In this CL process, the reaction of luminol with the oxovanadium(IV) ion produced from the decomposition of the oxovanadium(IV) complex in the reverse micelles is probably significant. A flow-injection method for the oxovanadium(IV) determination based on the present reversed micellar mediated CL reaction was examined. All the analytical conditions were optimized using the sample solution of oxovanadium(IV) acetylacetonate in chloroform. A detection limit (DL) of 0.1 ng cm(-3) and a linear calibration graph was obtained with a dynamic range from the DL to 50 ng cm(-3).
引用
收藏
页码:59 / 62
页数:4
相关论文
共 19 条
[1]  
COTTON FA, 1988, ADV INORG CHEM, P671
[2]   CATALYTIC BEHAVIOR OF IRON(III)-8-QUINOLINOL COMPLEX IN THE CHEMILUMINESCENCE REACTION OF LUMINOL WITH HYDROGEN-PEROXIDE IN REVERSE MICELLES [J].
FUJIWARA, T ;
TANIMOTO, N ;
NAKAHARA, K ;
KUMAMARU, T .
CHEMISTRY LETTERS, 1991, (07) :1137-1140
[3]   AUTOMATED-METHOD FOR THE SELECTIVE DETERMINATION OF GOLD BY ONLINE SOLVENT-EXTRACTION AND REVERSED MICELLAR-MEDIATED LUMINOL CHEMILUMINESCENCE DETECTION [J].
FUJIWARA, T ;
MURAYAMA, K ;
IMDADULLAH ;
KUMAMARU, T .
MICROCHEMICAL JOURNAL, 1994, 49 (2-3) :183-193
[4]   GENERATION OF CHEMI-LUMINESCENCE UPON REACTION OF IODINE WITH LUMINOL IN REVERSED MICELLES AND ITS ANALYTICAL APPLICABILITY [J].
FUJIWARA, T ;
TANIMOTO, N ;
HUANG, JJ ;
KUMAMARU, T .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2800-2803
[5]  
FUJIWARA T, 1990, SPECTROCHIM ACTA REV, V13, P399
[6]  
Hinze WL, 1990, ADV MULTIDIMENSIONAL, V1, P149
[7]  
HINZE WL, 1994, ORG ASSEM CHEM ANAL, V1, P37
[8]   EXPLOITATION OF REVERSED MICELLES AS A MEDIUM IN ANALYTICAL CHEMILUMINESCENCE MEASUREMENTS WITH APPLICATION TO THE DETERMINATION OF HYDROGEN-PEROXIDE USING LUMINOL [J].
HOSHINO, H ;
HINZE, WL .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :496-504
[9]   LUMINOL CHEMI-LUMINESCENT DETERMINATION OF GLUCOSE OR GLUCOSE-OXIDASE ACTIVITY USING AN INVERTED MICELLAR SYSTEM [J].
IGARASHI, S ;
HINZE, WL .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :446-450
[10]  
IMDADULLAH T, 1994, ANAL CHIM ACTA, V292, P151