Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers

被引:71
作者
Bezemer, Rick [1 ,2 ]
Lima, Alexandre [1 ]
Myers, Dean [3 ]
Klijn, Eva [1 ]
Heger, Michal [4 ]
Goedhart, Peter T. [2 ]
Bakker, Jan [1 ]
Ince, Can [1 ,2 ]
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Intens Care, NL-3015 CE Rotterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Translat Physiol, NL-1105 AZ Amsterdam, Netherlands
[3] Hutchinson Technol Inc, Hutchinson, MN 55350 USA
[4] Univ Amsterdam, Acad Med Ctr, Dept Expt Surg, NL-1105 AZ Amsterdam, Netherlands
来源
CRITICAL CARE | 2009年 / 13卷
关键词
MICROCIRCULATION; DYSFUNCTION; FAILURE;
D O I
10.1186/cc8002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: To assess potential metabolic and microcirculatory alterations in critically ill patients, near-infrared spectroscopy (NIRS) has been used, in combination with a vascular occlusion test (VOT), for the non-invasive measurement of tissue oxygen saturation (StO(2)), oxygen consumption, and microvascular reperfusion and reactivity. The methodologies for assessing StO(2) during a VOT, however, are very inconsistent in the literature and, consequently, results vary from study to study, making data comparison difficult and potentially inadequate. Two major aspects concerning the inconsistent methodology are measurement site and probe spacing. To address these issues, we investigated the effects of probe spacing and measurement site using 15 mm and 25 mm probe spacings on the thenar and the forearm in healthy volunteers and quantified baseline, ischemic, reperfusion, and hyperemic VOT-derived StO(2) variables. Methods: StO(2) was non-invasively measured in the forearm and thenar in eight healthy volunteers during 3-minute VOTs using two InSpectra tissue spectrometers equipped with a 15 mm probe or a 25 mm probe. VOT-derived StO(2) traces were analyzed for baseline, ischemic, reperfusion, and hyperemic parameters. Data were categorized into four groups: 15 mm probe on the forearm (F-15mm), 25 mm probe on the forearm (F-25mm), 15 mm probe on the thenar (T-15mm), and 25 mm probe on the thenar (T-25mm). Results: Although not apparent at baseline, probe spacing and measurement site significantly influenced VOT-derived StO(2) variables. For F-15mm, F-25mm, T-15mm, and T-25mm, StO(2) downslope was -6.4 +/- 1.7%/minute, -10.0 +/- 3.2%/minute, -12.5 +/- 3.0%/minute, and -36.7 +/- 4.6%/minute, respectively. StO(2) upslope was 105 +/- 34%/minute, 158 +/- 55%/minute, 226 +/- 41%/minute, and 713 +/- 101%/minute, and the area under the hyperemic curve was 7.4 +/- 3.8%.minute, 10.1 +/- 4.9%.minute, 12.6 +/- 4.4%.minute, and 21.2 +/- 2.7%.minute in these groups, respectively. Furthermore, the StO(2) parameters of the hyperemic phase of the VOT, such as the area under the curve, significantly correlated to the minimum StO(2) during ischemia. Conclusions: NIRS measurements in combination with a VOT are measurement site-dependent and probe-dependent. Whether this dependence is anatomy-, physiology-, or perhaps technology-related remains to be elucidated. Our study also indicated that reactive hyperemia depends on the extent of ischemic insult.
引用
收藏
页数:7
相关论文
共 18 条
[1]   MICROVASCULAR FUNCTION AND RHEOLOGICAL CHANGES IN HYPERDYNAMIC SEPSIS [J].
ASTIZ, ME ;
DEGENT, GE ;
LIN, RY ;
RACKOW, EC .
CRITICAL CARE MEDICINE, 1995, 23 (02) :265-271
[2]   Quantifying bedside-derived imaging of microcirculatory abnormalities in septic patients: a prospective validation study [J].
Boerma, EC ;
Mathura, KR ;
van der Voort, PHJ ;
Spronk, PE ;
Ince, C .
CRITICAL CARE, 2005, 9 (06) :R601-R606
[3]   The prognostic value of muscle StO2 in septic patients [J].
Creteur, Jacques ;
Carollo, Tiziana ;
Soldati, Giulia ;
Buchele, Gustavo ;
De Backer, Daniel ;
Vincent, Jean-Louis .
INTENSIVE CARE MEDICINE, 2007, 33 (09) :1549-1556
[4]   Microvascular blood flow is altered in patients with sepsis [J].
De Backer, D ;
Creteur, J ;
Preiser, JC ;
Dubois, MJ ;
Vincent, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) :98-104
[5]   Microvascular dysfunction and skeletal muscle oxygenation assessed by phase-modulation near-infrared spectroscopy in patients with septic shock [J].
De Blasi, RA ;
Palmisani, S ;
Alampi, D ;
Mercieri, M ;
Romano, R ;
Collini, S ;
Pinto, G .
INTENSIVE CARE MEDICINE, 2005, 31 (12) :1661-1668
[6]   Impairments in microvascular reactivity are related to organ failure in human sepsis [J].
Doerschug, Kevin C. ;
Delsing, Angela S. ;
Schmidt, Gregory A. ;
Haynes, William G. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 293 (02) :H1065-H1071
[7]   Cytopathic hypoxia - Mitochondrial dysfunction as mechanism contributing to organ dysfunction in sepsis [J].
Fink, MP .
CRITICAL CARE CLINICS, 2001, 17 (01) :219-+
[8]   Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O2 saturation response [J].
Gomez, Hernando ;
Torres, Andres ;
Polanco, Patricio ;
Kim, Hyung Kook ;
Zenker, Sven ;
Puyana, Juan Carlos ;
Pinsky, Michael R. .
INTENSIVE CARE MEDICINE, 2008, 34 (09) :1600-1607
[9]   Microcirculatory oxygenation and shunting in sepsis and shock [J].
Ince, C ;
Sinaasappel, M .
CRITICAL CARE MEDICINE, 1999, 27 (07) :1369-1377
[10]   The microcirculation is the motor of sepsis [J].
Ince, C .
CRITICAL CARE, 2005, 9 (Suppl 4) :S13-S19