Quantitation of the large polypeptide glucagon by protein precipitation and LC/MS

被引:25
作者
Delinsky, DC [1 ]
Hill, KT [1 ]
White, CA [1 ]
Bartlett, MG [1 ]
机构
[1] Univ Georgia, Dept Pharmaceut & Biomed Sci, Athens, GA 30602 USA
关键词
peptide; quantitation; polypeptide; LC/MS; protein precipitation;
D O I
10.1002/bmc.380
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a method for the quantitation of glucagon from rat plasma by protein precipitation and LC/MS. No internal standard was used, as a labeled standard was not available and similar peptides did not show comparable extraction characteristics to glucagon. The LC system included a Keystone C-18, 300 Angstrom pore size column; a linear gradient was used with a mobile phase consisting of water and acetonitrile, each with 0.2% acetic acid and 0.02% trifluoroacetic acid. Glucagon was detected with the mass spectrometer in positive ion mode monitoring the 4+ charge state at m/z 871.7. The method had an approximated limit of detection of 1 ng/mL. The lower limit of quantitation (LLOQ) was 25 ng/mL (7.2 fmol/mL), which could be reduced with an appropriate internal standard. External calibration was used and calibration curves were found to be linear over the range from 25 to 1000 ng/mL (7.2 to 290 fmol/mL). The method showed a high degree of precision and accuracy both within and between runs at four validation points, including the LLOQ. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:700 / 705
页数:6
相关论文
共 21 条
[1]   Determination of a cyclic hexapeptide, a novel antifungal agent, in human plasma by high-performance liquid chromatography with ion spray and turbo ion spray tandem mass spectrometric detection [J].
Chavez-Eng, CM ;
Schwartz, M ;
Constanzer, ML ;
Matuszewski, BK .
JOURNAL OF CHROMATOGRAPHY B, 1999, 721 (02) :229-238
[2]   Detection and quantitation of cellularly derived amyloid β peptides by immunoprecipitation-HPLC-MS [J].
Clarke, NJ ;
Tomlinson, AJ ;
Ohyagi, Y ;
Younkin, S ;
Naylor, S .
FEBS LETTERS, 1998, 430 (03) :419-423
[3]   A mass spectrometric method for quantitation of intact insulin in blood samples [J].
Darby, SM ;
Miller, ML ;
Allen, RO ;
LeBeau, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (01) :8-14
[4]   Growth hormone abuse in the horse: preliminary assessment of a mass spectrometric procedure for IGF-1 identification and quantitation [J].
de Kock, SS ;
Rodgers, JP ;
Swanepoel, BC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1191-1197
[5]   Electrospray LC-MS/MS quantitation, stability, and preliminary pharmacokinetics of bradykinin antagonist polypeptide B201 (NSC 710295) in the mouse [J].
Feng, WY ;
Chan, KK ;
Covey, JM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (3-4) :601-612
[6]   Effect of the mobile phase composition on the separation and detection of intact proteins by reversed-phase liquid chromatography -: electro spray mass spectrometry [J].
García, MC ;
Hogenboom, AC ;
Zappey, H ;
Irth, H .
JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) :187-199
[7]   Selective extraction of small proteins from biological samples using a novel restricted access column with cation exchange properties [J].
Grimm, CH ;
Boos, KS ;
Apel, C ;
Unger, KK ;
Önnerfjord, P ;
Heintz, L ;
Edholm, LE ;
Marko-Varga, G .
CHROMATOGRAPHIA, 2000, 52 (11-12) :703-709
[8]   Development of an isotope dilution assay for precise determination of insulin, C-peptide, and proinsulin levels in non-diabetic and type II diabetic individuals with comparison to immunoassay [J].
Kippen, AD ;
Cerini, F ;
Vadas, L ;
Stocklin, R ;
Vu, L ;
Offord, RE ;
Rose, K .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (19) :12513-12522
[9]   QUANTITATIVE-ANALYSIS OF SYNTHETIC HUMAN CALCITONIN BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
KOBAYASHI, N ;
KANAI, M ;
SETA, K ;
NAKAMURA, K .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 672 (01) :17-23
[10]   Measurement of the novel decapeptide cetrorelix in human plasma and urine by liquid chromatography-electrospray ionization mass spectrometry [J].
Niwa, M ;
Enomoto, K ;
Yamashita, K .
JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2) :245-253