On-line sample pre-treatment systems interfaced to electrothermal atomic absorption spectrometry

被引:25
作者
Burguera, JL [1 ]
Burguera, M [1 ]
机构
[1] Univ Los Andes, Fac Sci, Andean Inst Chem Res, IVAIQUIM, Merida 5101A, Venezuela
关键词
flow injection; electrothermal atomic absorption spectrometry; interface; on-line sample pre-treatment;
D O I
10.1039/a708112j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atomic spectrometric techniques working with a continuous supply of sample, such as flame atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry, are well suited for on-line connection through flow injection arrangements. For the determination of elements at lower concentrations, electrothermal atomization is often needed owing to the requirement for better detection limits, However, connecting a batch technique such as electrothermal atomic absorption spectrometry to a continuous flow or a flow injection system presents some fundamental difficulties, making it a real challenge for the analytical chemist to design suitable interfaces, There are different ways of interfacing the systems to each other; the available versions utilize either on-line sample treatment with off-line measurement or are completely on-line arrangements. Complex samples cannot be directly processed by this technique owing to severe matrix interferences, which have not been minimized despite the development of efficient background correction devices. Successful matrix separation can be achieved on-line through solvent and sorbent extraction, precipitation and coprecipitation, volatile compound generation and liquid chromatography. Moreover, transformation of the sample and/or its fractions into a form that can be analyzed in a graphite furnace often requires unpleasant, tedious and time-consuming digestion procedures. Microwave heating has emerged as a means of dramatically improving leaching, mineralization or digestion processes and has frequently been used with in-batch or on-line systems, This paper outlines the most recent advances in the development of flow injection-graphite furnace interfaces and also describes the on-line sample pre-treatment systems developed so far for electrothermal atomic absorption detection.
引用
收藏
页码:561 / 569
页数:9
相关论文
共 98 条
[1]  
ALCOCK NW, 1995, ANAL CHEM, V67, pR503
[2]   FLOW-THROUGH MICROWAVE DIGESTION SYSTEM FOR THE DETERMINATION OF ALUMINUM IN SHELLFISH BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
ARRUDA, MAZ ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (07) :501-504
[3]   DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION [J].
AZEREDO, LC ;
STURGEON, RE ;
CURTIUS, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) :91-98
[4]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[5]   SAMPLE WORK-UP FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING CONTINUOUS-FLOW EXTRACTION [J].
BACKSTROM, K ;
DANIELSSON, LG ;
NORD, L .
ANALYST, 1984, 109 :323-325
[6]  
BACKSTROM K, 1988, ANAL CHEM, V60, P1354
[7]   FLOW-INJECTION THERMOSPRAY SAMPLE DEPOSITION FOR ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY [J].
BANK, PC ;
DELOOSVOLLEBREGT, MTC ;
DEGALAN, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (08) :983-987
[8]   FLOW-INJECTION THERMOSPRAY SAMPLE DEPOSITION FOR ELECTROTHERMAL ATOMIZATION-ATOMIC ABSORPTION SPECTROMETRY [J].
BANK, PC ;
DELOOSVOLLEBREGT, MTC ;
DEGALAN, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (06) :571-579
[9]   EVALUATION OF COLD VAPOR FURNACE ATOMIC NONTHERMAL EXCITATION SPECTROMETRY FOR THE DETERMINATION OF MERCURY IN ENVIRONMENTAL-SAMPLES [J].
BAXTER, DC ;
NICHOL, R ;
LITTLEJOHN, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (10) :1155-1163
[10]   DETERMINATION OF MERCURY BY ATOMIC-ABSORPTION SPECTROMETRY USING A PLATINUM-LINED GRAPHITE-FURNACE FOR INSITU PRECONCENTRATION [J].
BAXTER, DC ;
FRECH, W .
ANALYTICA CHIMICA ACTA, 1989, 225 (01) :175-183