Direct determination of ethanol and methanol in liquid samples by means of vapor phase-Fourier transform infrared spectrometry

被引:50
作者
Garrigues, JM [1 ]
Perez-Ponce, A [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
Fourier transform infrared; ethanol and methanol determination; flow analysis; alcohol beverages; cosmetics;
D O I
10.1016/S0924-2031(97)00038-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A FTIR procedure is proposed for the direct determination of methanol and ethanol in liquid samples, such as alcoholic beverages and eau-de-cologne, based on vapor generation from small injected volumes of untreated samples into a heated Pyrex glass reactor in which, at a temperature of 80 degrees C, ethanol and methanol are volatilized and introduced into a long-path IR gas cell by means of a N-2 carrier flow. The IR spectra obtained present two characteristic ethanol bands (1050 and 880 cm(-1)) and a single characteristic methanol band (1030 cm(-1)). The measurement of the area of the transient recording obtained for the wavenumber range between 1025-950 and 950-820 cm(-1) allows us the determination of ethanol and methanol in the same sample by using a simple proportional equations approach. The limit of detection values found for an injection volume of 1 mu l were 0.21% v/v for ethanol and 0.04% v/v for methanol and the relative standard deviation values were between 0.5 and 1.4% for five analyses of samples containing between 30-80% v/v of ethanol and 0.5-3.5% v/v of methanol. Acetone, ethyl acetate, 1-propanol and 2-propanol do not interfere with this determination at concentration levels about those of methanol. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:219 / 228
页数:10
相关论文
共 20 条
  • [1] *AOAC, 1995, OFF METH AN ASS OFF
  • [2] AUTOMATED DETECTION OF METHANOL VAPOR BY OPEN-PATH FOURIER-TRANSFORM INFRARED SPECTROMETRY
    BANGALORE, AS
    SMALL, GW
    COMBS, RJ
    KNAPP, RB
    KROUTIL, RT
    [J]. ANALYTICA CHIMICA ACTA, 1994, 297 (03) : 387 - 403
  • [3] DETECTION OF METHANOL IN GASOLINES USING NEAR-INFRARED SPECTROSCOPY AND AN OPTICAL FIBER
    BUCHANAN, BR
    HONIGS, DE
    [J]. APPLIED SPECTROSCOPY, 1987, 41 (08) : 1388 - 1392
  • [4] CAI XY, 1995, HEWLETTPACKARD PEAK, V3, P10
  • [5] CHA S, 1986, OPT ENG, V25, P11
  • [6] THERMAL LENS SPECTROPHOTOMETRY OF GASEOUS HYDROCARBON MOLECULES IN THE INFRARED REGION
    HIGASHI, T
    IMASAKA, T
    ISHIBASHI, N
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (12) : 2010 - 2013
  • [7] HUNSON MK, 1995, ANAL CHEM, V59, P2603
  • [8] THE QUANTITATIVE-ANALYSIS OF A MODEL FERMENTATION BROTH
    KUEHL, D
    CROCOMBE, R
    [J]. APPLIED SPECTROSCOPY, 1984, 38 (06) : 907 - 909
  • [9] USE OF A COMBINED GC/FTIR/MS SYSTEM FOR THE ANALYSIS OF SPIRITS
    LABER, H
    SCHULZ, J
    SPONHOLZ, WR
    BREMSER, W
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (06): : 530 - 535
  • [10] Vapour generation Fourier transform infrared spectrometric determination of benzene, toluene and methyl tert.-butyl ether in gasolines
    LopezAnreus, E
    Garrigues, S
    delaGuardia, M
    [J]. ANALYTICA CHIMICA ACTA, 1996, 333 (1-2) : 157 - 165