Multipole shimming of permanent magnets using harmonic corrector rings

被引:33
作者
Jachmann, R. C. [1 ]
Trease, D. R.
Bouchard, L. -S.
Sakellariou, D.
Martin, R. W.
Schlueter, R. D.
Budinger, T. F.
Pines, A.
机构
[1] Lawrence Berkeley Natl Lab, Div Sci Mat, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[3] CEA Saclay, Lab Struct & Dynam Resonance Magnet, Comis Nacl Energia Atom, Serv Chim Mol, F-91191 Gif Sur Yvette, France
[4] Univ Calif Irvine, Dept Chem, Irvine, CA 92697 USA
[5] Lawrence Berkeley Natl Lab, Div Engn, Berkeley, CA 94720 USA
[6] Lawrence Berkeley Natl Lab, Div Life Sci, Berkeley, CA 94720 USA
关键词
D O I
10.1063/1.2713438
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Shimming systems are required to provide sufficient field homogeneity for high resolution nuclear magnetic resonance (NMR). In certain specialized applications, such as rotating-field NMR and mobile ex situ NMR, permanent magnet-based shimming systems can provide considerable advantages. We present a simple two-dimensional shimming method based on harmonic corrector rings which can provide arbitrary multipole order shimming corrections. Results demonstrate, for example, that quadrupolar order shimming improves the linewidth by up to an order of magnitude. An additional order of magnitude reduction is in principle achievable by utilizing this shimming method for z-gradient correction and higher order xy gradients. (c) 2007 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 8 条
[1]  
HAEBERLEN U, 1976, ADV MAG RESON S, V1
[2]   DESIGN OF PERMANENT MULTIPOLE MAGNETS WITH ORIENTED RARE-EARTH COBALT MATERIAL [J].
HALBACH, K .
NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (01) :1-10
[3]   High-resolution NMR of static samples by rotation of the magnetic field [J].
Meriles, CA ;
Sakellariou, D ;
Moulé, A ;
Goldman, M ;
Budinger, TF ;
Pines, A .
JOURNAL OF MAGNETIC RESONANCE, 2004, 169 (01) :13-18
[4]   Miniature permanent magnet for table-top NMR [J].
Moresi, G ;
Magin, R .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2003, 19B (01) :35-43
[5]   Design and construction of a dipolar Halbach array with a homogeneous field from identical bar magnets:: NMR Mandhalas [J].
Raich, H ;
Blümler, P .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 23B (01) :16-25
[6]   High-resolution NMR of anisotropic samples with spinning away from the magic angle [J].
Sakellariou, D ;
Meriles, CA ;
Martin, RW ;
Pines, A .
CHEMICAL PHYSICS LETTERS, 2003, 377 (3-4) :333-339
[7]   Three-dimensional pure permanent magnet undulator design theory [J].
Schlueter, RD ;
Marks, S .
IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (04) :2710-2713
[8]   Pure permanent magnet harmonics corrector ring [J].
Schlueter, RD ;
Humphries, D ;
Tanabe, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (02) :153-158