Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients Clinical article

被引:105
作者
Amato, Vincenzo [1 ]
Giannachi, Luigi [1 ]
Irace, Claudio [1 ]
Corona, Claudio [1 ]
机构
[1] Casa Cura Igea, Neurosurg Unit, I-20133 Milan, Italy
关键词
pedicle screw; screw misplacement; spinal fusion; spinal instrumentation; transpedicular screw fixation; LUMBAR INTERBODY FUSION; INTERNAL-FIXATION; PLAIN RADIOGRAPHS; COMPLICATIONS; INSERTION; SPONDYLOLISTHESIS; THORACOLUMBAR; OUTCOMES; SURGERY;
D O I
10.3171/2009.9.SPINE09261
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Object. The goal of this study was to determine the incidence of screw misplacement and complications in a group of 102 patients who underwent transpedicle screw fixation in the lumbosacral spine with conventional open technique and intraoperative fluoroscopy. The results are compared with published data. Methods. Cases involving 102 consecutive patients (424 inserted screws) were reviewed. Surgery was performed in all cases by the same surgeon's team, using the same implant, and all results were assessed by means of a specific CT protocol. The screw position was assessed by the authors and an independent observer. Screw position wits classified as correct when the screw wits completely surrounded by the pedicle cortex, as "cortical encroachment" (questionable violation) if the pedicle cortex could not be visualized, and as "frank penetration" when the screw was outside the pedicular boundaries. Frank penetration was further subdivided as minor (when the edge of the screw thread was up to 2.0 mm outside the pedicle cortex), moderate (2.1-4 mm). and severe (> 4 mm). The incidence of intra- and postoperative complications not related to screw position its well as hardware failures were also registered, with a minimum follow-up duration of 8 months. Results. The rate of frank pedicle screw misplacement was 5%. The rate of minimal or questionable pedicle wall violation was 2.8%. Among the frank misplacements, 6 were classified as minor. 12 as moderate, and 3 as severe penetration. Two patients (2%) had radicular pain and neurological deficits (inferomedial and inferolateral minor misplacement at L-4 and L-5. respectively), and 5 patients (4.9%) complained only of radicular pain. At the follow-up examination all patients had completely recovered their neurological function and radicular pain was resolved in all cases. The complications not related to screw malposition were 2 pedicle fractures (2% of patients), 1 nerve root injury (1%), and 1 dural laceration (1%). Five patients (4.8%) had postoperative anemia and required transfusions. Superficial or deep wound infection was noted in 3 patients (2.9%). Late hardware failure occurred in 2 patients (2%). One patient developed adjacent segmental instability and required additional Surgery to extend the fusion. Conclusions. Our rates of screw misplacement and complications compare favorably with the lowest rates of the series in which conventional technique was used and are close to the rates reported for image-guided methods. The risk of malpositioning may be reduced with careful preoperative surgical planning, accurate knowledge of the spinal anatomy, surgical experience, and correct indication for conventional surgery. The conventional technique still mains a practical, safe, and effective surgical method for lumbosacral fixation. (DOI: 10.3171/2009.9.SPINE09261)
引用
收藏
页码:306 / 313
页数:8
相关论文
共 39 条
[1]
The effect of transpedicular screw misplacement on late spinal stability [J].
Açikbas, SC ;
Arslan, FY ;
Tuncer, MR .
ACTA NEUROCHIRURGICA, 2003, 145 (11) :949-955
[2]
Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine [J].
Amiot, LP ;
Lang, K ;
Putzier, M ;
Zippel, H ;
Labelle, H .
SPINE, 2000, 25 (05) :606-614
[3]
Lumbar pedicle: surgical anatomic evaluation and relationships [J].
Attar, A ;
Ugur, HC ;
Uz, A ;
Tekdemir, I ;
Egemen, N ;
Genc, Y .
EUROPEAN SPINE JOURNAL, 2001, 10 (01) :10-15
[4]
Image-guided spine surgery - A cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models [J].
Austin, MS ;
Vaccaro, AR ;
Brislin, B ;
Nachwalter, R ;
Hilibrand, AS ;
Albert, TJ .
SPINE, 2002, 27 (22) :2503-2508
[5]
Complications of pediatric thoracolumbar and lumbar pedicle screws [J].
Brown, CA ;
Lenke, LG ;
Bridwell, KH ;
Geideman, WM ;
Hasan, SA ;
Blanke, K .
SPINE, 1998, 23 (14) :1566-1571
[6]
Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[7]
Stepwise methodology for plain radiographic assessment of pedicle screw placement: A comparison with computed tomography [J].
Choma, Theodore J. ;
Denis, Francis ;
Lonstein, John E. ;
Perra, Joseph H. ;
Schwender, James D. ;
Garvey, Timothy A. ;
Mullin, William J. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (08) :547-553
[8]
Anatomic relations between the lumbar pedicle and the adjacent neural structures [J].
Ebraheim, NA ;
Xu, RM ;
Darwich, M ;
Yeasting, RA .
SPINE, 1997, 22 (20) :2338-2341
[9]
ACCURACY OF PEDICLE SCREW PLACEMENT IN LUMBAR FUSIONS BY PLAIN RADIOGRAPHS AND COMPUTED-TOMOGRAPHY [J].
FARBER, GL ;
PLACE, HM ;
MAZUR, RA ;
JONES, DEC ;
DAMIANO, TR .
SPINE, 1995, 20 (13) :1494-1499
[10]
1997 Volvo Award winner in clinical studies - Degenerative lumbar spondylolisthesis with spinal stenosis: A prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation [J].
Fischgrund, JS ;
Mackay, M ;
Herkowitz, HN ;
Brower, R ;
Montgomery, DM ;
Kurz, LT .
SPINE, 1997, 22 (24) :2807-2812