Requirements for growing tissue-engineered vascular grafts

被引:160
作者
Mitchell, SL
Niklason, LE
机构
[1] Duke Univ, Dept Anesthesia, Durham, NC 27708 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
D O I
10.1016/S1054-8807(02)00183-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Small diameter (< 6 mm) vascular grafts are in large demand for coronary and peripheral bypass procedures. Although synthetic grafts have been developed, tissue-based vascular grafts that can better mimic native vessels will likely yield superior results. The success of a tissue-based graft depends on its ability to meet several requirements. First, a graft must possess a confluent, adherent and quiescent endothelium to resist thrombosis in vivo. The mechanical behavior of the graft must mimic the mechanical properties of a native vessel. Hence, a graft must have a highly organized collagen matrix to impart tissue strength. Finally, a graft must contain an elastin network to provide compliance and recoil. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 34 条
  • [1] EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY
    ABBOTT, WM
    MEGERMAN, J
    HASSON, JE
    LITALIEN, G
    WARNOCK, DF
    [J]. JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) : 376 - 382
  • [2] *AM HEART ASS, 2002, BIOST FACT SHEET CAR
  • [3] ASSESSMENT OF ELASTIN AND COLLAGEN CONTRIBUTION TO AORTIC ELASTICITY IN CONSCIOUS DOGS
    ARMENTANO, RL
    LEVENSON, J
    BARRA, JG
    FISCHER, EIC
    BREITBART, GJ
    PICHEL, RH
    SIMON, A
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 260 (06): : H1870 - H1877
  • [4] Contribution of collagen, elastin, and smooth muscle to in vivo human brachial artery wall stress and elastic modulus
    Bank, AJ
    Wang, HY
    Holte, JE
    Mullen, K
    Shammas, R
    Kubo, SH
    [J]. CIRCULATION, 1996, 94 (12) : 3263 - 3270
  • [5] Engineered alignment in media equivalents: Magnetic prealignment and Mandrel compaction
    Barocas, VH
    Girton, TS
    Tranquillo, RT
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (05): : 660 - 666
  • [6] ASSESSMENT OF SMOOTH-MUSCLE CONTRIBUTION TO DESCENDING THORACIC AORTIC ELASTIC MECHANICS IN CONSCIOUS DOGS
    BARRA, JG
    ARMENTANO, RL
    LEVENSON, J
    FISCHER, EIC
    PICHEL, RH
    SIMON, A
    [J]. CIRCULATION RESEARCH, 1993, 73 (06) : 1040 - 1050
  • [7] VEIN COMPLIANCE - A PREOPERATIVE INDICATOR OF VEIN MORPHOLOGY AND OF VEINS AT RISK OF VASCULAR GRAFT STENOSIS
    DAVIES, AH
    MAGEE, TR
    BAIRD, RN
    SHEFFIELD, E
    HORROCKS, M
    [J]. BRITISH JOURNAL OF SURGERY, 1992, 79 (10) : 1019 - 1021
  • [8] DOBRIN PB, 1984, ARCH SURG-CHICAGO, V119, P405
  • [9] ACC/AHA guidelines for Coronary Artery Bypass Graft Surgery: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to revise the 1991 Guidelines on Coronary Artery Bypass Graft Surgery)
    Eagle, KA
    Guyton, RA
    Davidoff, R
    Ewy, GA
    Fonger, S
    Gardner, TJ
    Gott, JP
    Herrmann, HC
    Marlow, RA
    Nugent, WC
    O'Connor, GT
    Orszulak, TA
    Rieselbach, RE
    Winters, WL
    Yusuf, S
    Gibbons, RJ
    Alpert, JS
    Eagle, KA
    Gardner, TJ
    Garson, A
    Gregoratos, G
    Russell, RO
    Smith, SC
    McEntee, CW
    Elma, MA
    Pigman, GC
    Starke, RD
    Taubert, KA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (04) : 1262 - 1342
  • [10] CROSS-LINKING IN COLLAGEN AND ELASTIN
    EYRE, DR
    PAZ, MA
    GALLOP, PM
    [J]. ANNUAL REVIEW OF BIOCHEMISTRY, 1984, 53 : 717 - 748