Final results of the Lung Screening Study, a randomized feasibility study of spiral CT versus chest X-ray screening for lung cancer

被引:244
作者
Gohagan, JK [1 ]
Marcus, PM [1 ]
Fagerstrom, RM [1 ]
Pinsky, PF [1 ]
Kramer, BS [1 ]
Prorok, PC [1 ]
Ascher, S [1 ]
Bailey, W [1 ]
Brewer, B [1 ]
Church, T [1 ]
Engelhard, D [1 ]
Ford, M [1 ]
Fouad, M [1 ]
Freedman, M [1 ]
Gelmann, E [1 ]
Gierada, D [1 ]
Hocking, W [1 ]
Inampudi, S [1 ]
Irons, B [1 ]
Johnson, CC [1 ]
Jones, A [1 ]
Kucera, G [1 ]
Kvale, P [1 ]
Lappe, K [1 ]
Manor, W [1 ]
Moore, A [1 ]
Nath, H [1 ]
Neff, S [1 ]
Oken, M [1 ]
Plunkett, M [1 ]
Price, H [1 ]
Reding, D [1 ]
Riley, T [1 ]
Schwartz, M [1 ]
Spizarny, D [1 ]
Yoffie, R [1 ]
Zylak, C [1 ]
机构
[1] NCI, Div Canc Prevent, Bethesda, MD 20892 USA
关键词
chest X-ray; lung cancer; randomized trial; screening; spiral CT;
D O I
10.1016/j.lungcan.2004.06.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The Lung Screening Study (LSS) was a pilot study designed to assess the feasibility of conducting a large scale randomized controlled trial (RCT) of low radiation dose spiral computed tomography (LDCT) versus chest X-ray (CXR) for lung cancer screening. Baseline results of LSS have been previously reported. Here, we report on the findings at the year one screen and on the final results of the LSS study. A total of 1660 subjects were randomized to the LDCT arm and 1658 to the CXR arm. Compliance with screening declined from 96% at baseline to 86% at year one in the LDCT arm and declined from 93% at baseline to 80% at year one in the CXR arm. Positivity rates for the year one screen were 25.8% for LDCT and 8.7% for CXR. Cancer yield was significantly less at year one for LDCT, 0.57%, than at baseline, 1.9%; cancer yield for CXR increased from 0.45% at baseline to 0.68% at year one. Forty lung cancers in the LDCT arm and 20 in the CXR arm were diagnosed over the study period. Stage I cancers comprised 48% of cases in the LDCT arm and 40% in the CXR arm. A total of 16 stage III-IV cancers were observed in the LDCT arm versus nine in the CXR arm. The LSS has established the feasibility of a RCT comparing annual spiral CT to chest X-ray for lung cancer screening. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 15 条
[1]   Chest radiography as the comparison for spiral CT in the National Lung Screening Trial [J].
Church, TR .
ACADEMIC RADIOLOGY, 2003, 10 (06) :713-715
[2]   LUNG-CANCER SCREENING - THE MAYO PROGRAM [J].
FONTANA, RS ;
SANDERSON, DR ;
WOOLNER, LB ;
TAYLOR, WF ;
MILLER, WE ;
MUHM, JR .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1986, 28 (08) :746-750
[3]  
FROST JK, 1984, AM REV RESPIR DIS, V130, P549
[4]   Baseline findings of a randomized feasibility trial of lung cancer screening with spiral CT scan vs chest radiograph - The Lung Screening Study of the National Cancer Institute [J].
Gohagan, J ;
Marcus, P ;
Fagerstrom, R ;
Pinsky, P ;
Kramer, B ;
Prorok, P .
CHEST, 2004, 126 (01) :114-121
[5]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[6]  
HENSCHKE CI, EARLY LUNG CANC ACTI
[7]   Annual report to the nation on the status of cancer (1973 through 1998), featuring cancers with recent increasing trends [J].
Howe, HL ;
Wingo, PA ;
Thun, MJ ;
Ries, LAG ;
Rosenberg, HM ;
Feigal, EG ;
Edwards, BK .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2001, 93 (11) :824-842
[8]   NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[9]  
KUBIK A, 1986, CANCER-AM CANCER SOC, V57, P2427, DOI 10.1002/1097-0142(19860615)57:12<2427::AID-CNCR2820571230>3.0.CO
[10]  
2-M