Orbital reconstruction with individually copy-milled ceramic implants

被引:65
作者
Hoffmann, J
Cornelius, CP
Groten, M
Pröbster, L
Pfannenberg, C
Schwenzer, N
机构
[1] Univ Tubingen, Dept Oral & Maxillofacial Surg, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Prosthodont, D-72076 Tubingen, Germany
[3] Univ Tubingen, Dept Radiol, D-72076 Tubingen, Germany
关键词
D O I
10.1097/00006534-199803000-00006
中图分类号
R61 [外科手术学];
学科分类号
摘要
Diagnostic advances such as computed tomography and new surgical techniques hare dramatically improved both the functional and aesthetic outcome of orbital reconstructions. Taking a further approach, we designed ceramic implants (Bioverit) on the basis of stereolithographic models. After copy milling a resin template with a commercially available dental unit (Celay), the prefabricated implants were inserted for reconstruction of the lamina papyracea (n = 1), zygomatic complex (n = 2), infraorbital floor (n = 5), and rim (n = 3). Intraoperatively, only slight modifications of the implants had to be performed. The results were encouraging, as all cases showed a good aesthetic and functional postoperative outcome. Preoperative evaluation of the osseous defect and prefabrication of the required implant reduced operating time and patient morbidity significantly.
引用
收藏
页码:604 / 612
页数:9
相关论文
共 30 条
[1]  
Beleites E., 1988, HNO PRAX, V13, P121
[2]   STEREOLITHOGRAPHY IN ORAL AND MAXILLOFACIAL OPERATION PLANNING [J].
BILL, JS ;
REUTHER, JF ;
DITTMANN, W ;
KUBLER, N ;
MEIER, JL ;
PISTNER, H ;
WITTENBERG, G .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 24 (01) :98-103
[3]   ORBITAL VOLUME MEASUREMENTS IN ENOPHTHALMOS USING 3-DIMENSIONAL CT IMAGING [J].
BITE, U ;
JACKSON, IT ;
FORBES, GS ;
GEHRING, DG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1985, 75 (04) :502-507
[4]   ORBITAL BLOWOUT FACTURES - A 10-YEAR SURVEY [J].
CONVERSE, JM ;
SMITH, B ;
OBEAR, MF ;
WOODSMIT.D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1967, 39 (01) :20-+
[5]  
Dougherty W R, 1994, J Craniofac Surg, V5, P26, DOI 10.1097/00001665-199402000-00007
[6]  
Eidenbenz S, 1994, PHILLIP J, V11, P91
[7]  
EIDENBENZ S, 1992, Patent No. 0480290
[8]  
GOLDBERG RA, 1993, OPHTHALMIC SURG LAS, V24, P190
[9]  
Habal M B, 1992, J Craniofac Surg, V3, P175, DOI 10.1097/00001665-199211000-00011
[10]   CORRECTION OF POSTTRAUMATIC ORBITAL DEFORMITIES - OPERATIVE TECHNIQUES AND REVIEW OF 26 PATIENTS [J].
HAMMER, B ;
PREIN, J .
JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY, 1995, 23 (02) :81-90