Characterization of a reservoir-type capillary optical microsensor for pCO2 measurements

被引:42
作者
Ertekin, K
Klimant, I
Neurauter, G
Wolfbeis, OS
机构
[1] Univ Celal Bayar, Dept Chem, Fac Sci & Arts, TR-45140 Muradiye, Manisa, Turkey
[2] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
[3] Graz Univ Technol, Inst Analyt Chem Micro & Radiochem, A-8010 Graz, Austria
关键词
carbon dioxide; fiber optic chemical sensor; capillary microsensor;
D O I
10.1016/S0039-9140(02)00495-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reservoir type of capillary microsensor for pCO(2) measurements is presented. The sensor is based on the measurement of the fluorescence intensity of the anionic form of the pH indicator 1-hydroxy-3,6,8-pyrenetrisulfonate in the form of its ion pair with a quaternary ammonium base in an ethyl cellulose matrix. The glass capillary containing the reservoir sensor was prepared by immersing the tip of the optical fiber into the sensing agent very close to the sensor tip thus providing a very small volume for the sensing reaction. The purpose of the sensing approach is to regenerate the dye/buffer system by diffusion, which may be poisoned by interfering acids, or bleach by photolysis. The fresh cocktail from the reservoir takes the place of protonated form of the dye. The internal buffer system also makes the protonation-deprotonation equilibria reversible. The distal tip of the internal buffer containing reservoir is coated with a gas-permeable but ion-impermeable teflon membrane. The dynamic range for the detection of PCO2 is between 1 and 20 hPa, which corresponds to the range of dissolved CO2 in water. The response time is 15 s and the detection limit is 1 hPa of PCO2. The recovery performance of this sensor can be improved by means of mechanical adjustment of the sensor tip in a micrometric scale. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 18 条
[1]   MEASUREMENT OF SEAWATER PCO2 USING A RENEWABLE-REAGENT FIBER OPTIC SENSOR WITH COLORIMETRIC DETECTION [J].
DEGRANDPRE, MD .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :331-337
[2]  
Heitzmann H., 1985, U.S. Patent, Patent No. [4.557.900, 4557900]
[3]   Carbon dioxide gas sensor with multivalent cation conducting solid electrolytes [J].
Imanaka, N ;
Kamikawa, M ;
Tamura, S ;
Adachi, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :301-306
[4]   FIBER-OPTIC SENSOR FOR CARBON-DIOXIDE WITH A PH-INDICATOR DISPERSED IN A POLY(ETHYLENE GLYCOL) MEMBRANE [J].
KAWABATA, Y ;
KAMICHIKA, T ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1989, 219 (02) :223-229
[5]  
LUBBERS DW, 1975, Z NATURFORSCH C, V30, P532
[6]   EQUILIBRIUM STUDIES ON COLORIMETRIC PLASTIC FILM SENSORS FOR CARBON-DIOXIDE [J].
MILLS, A ;
CHANG, Q ;
MCMURRAY, N .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1383-1389
[7]   Effect of plasticizer-polymer compatibility on the response characteristics of optical thin CO2 and O2 sensing films [J].
Mills, A ;
Lepre, A ;
Wild, L .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :193-202
[8]  
MILLS A, 1997, SENSOR ACTUAT B-CHEM, V38, P419
[9]   Fluorescence optical sensor for low concentrations of dissolved carbon dioxide [J].
Muller, B ;
Hauser, PC .
ANALYST, 1996, 121 (03) :339-343
[10]   A FIBER-OPTIC SENSOR FOR CO2 MEASUREMENT [J].
MUNKHOLM, C ;
WALT, DR ;
MILANOVICH, FP .
TALANTA, 1988, 35 (02) :109-112