Investigation of combwax of honeybees with high-temperature gas chromatography and high-temperature gas chromatography-chemical ionization mass spectrometry II: High-temperature gas chromatography-chemical ionization mass spectrometry

被引:53
作者
Aichholz, R [1 ]
Lorbeer, E
机构
[1] Novartis Pharma AG, Res, Core Technol Area, PSB, CH-4002 Basel, Switzerland
[2] Univ Vienna, Inst Organ Chem, A-1090 Vienna, Austria
关键词
beeswax; Apis spp; interfaces; GC-MS; instrumentation; mass spectrometry; lipids;
D O I
10.1016/S0021-9673(00)00386-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Crude combwax of six various honey bee species have been analyzed by high-temperature gas chromatography (HTGC)-chemical ionization mass spectrometry after a two-step silylation procedure. An optimized chromatographic procedure, described previously, enables the separation of high-molecular mass lipid compounds resulting in a characteristic fingerprint of the combwaxes of different honeybee species. The coupling of HTGC to mass spectrometry requires appropriate instrumentation in order to achieve sufficient sensitivity at high elution temperatures and avoid loss of chromatographic resolution. Chemical ionization was carried out using methane as reagent gas in order to determine the molecular mass of the individual compounds by means of abundant quasi molecular ions. To confirm the presence of unsaturated wax esters, ammonia was used as reagent gas. More than 80 lipid constituents were separated and characterized by their mass spectra. Representative chemical ionization mass spectra of individual compounds are presented. Both, HTGC-flame ionization detection data and the results of the HTGC-mass spectrometric investigations enabled a rapid profiling of the individual classes of compounds in crude combwaxes. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 88
页数:14
相关论文
共 20 条
[1]   Investigation of combwax of honeybees with high-temperature gas chromatography and high-temperature gas chromatography - chemical ionization mass spectrometry I. High-temperature gas chromatography [J].
Aichholz, R ;
Lorbeer, E .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (02) :601-615
[2]  
Aichholz R, 1996, J MICROCOLUMN SEP, V8, P553, DOI 10.1002/(SICI)1520-667X(1996)8:8<553::AID-MCS5>3.3.CO
[3]  
2-I
[4]  
ARSENAULT GP, 1970, CHEM COMMUN, V1, P1542
[5]   PARALLEL FLAME IONIZATION DETECTION-TOTAL ION CURRENT RECORDING IN CAPILLARY GAS CHROMATOGRAPHY-CHEMICALIONIZATION MASS-SPECTROMETRY [J].
BLUM, W ;
RICHTER, WJ .
JOURNAL OF CHROMATOGRAPHY, 1977, 132 (02) :249-259
[6]  
BLUM W, 1991, HOCHTEMPERATUR GAS C, P79
[7]  
BLUM W, 1990, J HIGH RES CHROMATOG, V13, P85
[8]  
BLUM W, 1975, FINNIGAN SPECTRA, V5, P3
[9]  
BLUM W, 1991, HOCHTEMPERATUR GAS C
[10]  
BLUM W, 1974, FINNIGAN SPECTRA, V4, P1