Validation of cardiologists' decisions to initiate reperfusion therapy for acute myocardial infarction with electrocardiograms viewed on liquid crystal displays of cellular telephones
被引:14
作者:
Leibrandt, PN
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
Leibrandt, PN
Bell, SJ
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
Bell, SJ
Savona, MR
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
Savona, MR
Pettis, KS
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
Pettis, KS
Selvester, RH
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
Selvester, RH
论文数: 引用数:
h-index:
机构:
Maynard, C
Warner, R
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
Warner, R
Wagner, GS
论文数: 0引用数: 0
h-index: 0
机构:Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
Wagner, GS
机构:
[1] Duke Univ, Clin Res Inst, ECG Core Lab, Med Ctr, Durham, NC 27705 USA
[2] Baylor Coll Med, Houston, TX 77030 USA
[3] Long Beach Mem Med Ctr, Long Beach, CA USA
[4] Univ Washington, Dept Hlth Serv, Seattle, WA 98195 USA
Background The transmission of 12-lead electrocardiograms from remote locations to hand-held computers of cardiologists is now possible with the development of wireless technology and computer software. This investigation determined whether the cardiologist's decisions regarding reperfusion therapy for patients with symptoms suggestive of an acute myocardial infarction are the same when given electrocardiograms displayed on a cellular telephone as on a standard paper recording. Methods Cardiologists were given 20 electrocardiograms of patients with acute chest pain suggestive of acute myocardial infarction to test the diagnostic reliability of the Nokia 9000i cellular telephone liquid crystal display (LCD) screen. The cardiologists made their decision to initiate or not initiate reperfusion therapy for the patients after viewing their electrocardiograms displayed on both 5-mm and l-mm formatted grids and twice on traditional printout electrocardiograms. The control level of intraobserver agreement between the responses from the 2 sets of paper display electrocardiograms was compared with the experimental level of intraobserver agreement between the l-mm LCD electrocardiograms and both sets of paper display electrocardiograms to determine whether the viewing medium affected the cardiologist's decisions. The l-mm and 5-mm ICD screen electrocardiograms were compared to determine if the grid size affected the cardiologist's decisions. Results Ninety-three percent of the 2 sets of paper-guided decisions were in agreement. When comparing the l-mm LCD-guided decisions with both sets of paper-guided decisions, 94% and 89% of the decisions, respectively, were in agreement The differences between the control and experimental degrees of intraobserver agreement of 1% and 4% were not statistically significant (P1 =.81, P2 =.29). Ninety-one percent of the l-mm LCD-guided decisions were in agreement with the 5-mm LCD-guided decisions. Conclusions Cardiologists' decisions did not vary significantly when viewing either traditional paper electrocardiograms or LCD screen electrocardiograms. Even though there was not a significant difference in the cardiologists' decisions when they viewed electrocardiograms displayed on both the l-mm and 5-mm grid, it is recommended that the l-mm grid be used for clinical implementation of the ICD screen.
引用
收藏
页码:747 / 752
页数:6
相关论文
共 20 条
[1]
ARNTZ HR, 1992, AM J CARDIOL, V70, P417, DOI 10.1016/0002-9149(92)91182-4