Infectious complications associated with ventricular assist systems

被引:52
作者
Myers, TJ [1 ]
Khan, T [1 ]
Frazier, OH [1 ]
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Cullen Cardiovasc Res Labs, Houston, TX 77225 USA
关键词
D O I
10.1097/00002480-200011000-00034
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Infectious complications during support with a ventricular assist system (VAS) can cause severe morbidity and mortality, affecting nearly one-half of all VAS recipients. Because of the lack of a uniform definition of infection, the incidence of this complication is hard to determine accurately. It is approximately 50% for patients being supported by an implantable VAS as a bridge to heart transplantation and 28% for patients supported by an external, short-term VAS. Infections can be classified according to the involvement or noninvolvement of the implanted device and according to the severity of the infection. Severe infections involving the implanted device may preclude heart transplantation for some patients, but numerous patients with milder infections have undergone successful transplantation. Numerous factors predispose VAS patients to infection. Postoperative bleeding necessitating reoperation is an important contributing factor. Endotracheal tubes, intravascular catheters, and other indwelling tubes necessary for the care of postsurgical patients are also common routes of contamination. Control of infection may be improved with new VAS designs, antibiotic impregnated drivelines, and innovative therapies such as antibiotic beads. The next generation of VASs should be inherently less susceptible to infection because of their smaller size, reduced thrombogenicity, and better flow characteristics. In addition to more effective antibiotics, improved VAS designs that incorporate transcutaneous energy transmission systems may reduce infectious complications and allow safe, long-term VAS support.
引用
收藏
页码:S28 / S36
页数:9
相关论文
共 65 条
[1]   Activation-induced T-cell death and immune dysfunction after implantation of left-ventricular assist device [J].
Ankersmit, HJ ;
Tugulea, S ;
Spanier, T ;
Weinberg, AD ;
Artrip, JH ;
Burke, EM ;
Flannery, M ;
Mancini, D ;
Rose, EA ;
Edwards, NM ;
Oz, MC ;
Itescu, S .
LANCET, 1999, 354 (9178) :550-555
[2]  
[Anonymous], AM SOC ARTIF INT ORG
[3]  
Argenziano M, 1997, J HEART LUNG TRANSPL, V16, P822
[4]  
BURCHARD KW, 1983, ARCH SURG-CHICAGO, V118, P217
[5]   INFECTIONS ASSOCIATED WITH IMPLANTED BLOOD PUMPS [J].
BURNS, GL .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (11) :771-776
[6]  
CAPEK P, 1995, ASAIO J, V38, pM543
[7]   COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS - EVIDENCE FOR GENERATION OF C3A AND C5A ANAPHYLATOXINS [J].
CHENOWETH, DE ;
COOPER, SW ;
HUGLI, TE ;
STEWART, RW ;
BLACKSTONE, EH ;
KIRKLIN, JW .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (09) :497-503
[8]  
CHIANG BY, 1991, T ASAIO, V37, pM256
[9]   Development of an infection-resistant LVAD driveline: A novel approach to the prevention of device-related infections [J].
Choi, L ;
Choudhri, AF ;
Pillarisetty, VG ;
Sampath, LA ;
Caraos, L ;
Brunnert, SR ;
Oz, MC ;
Modak, SM .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (11) :1103-1110
[10]   Bacterial biofilms: A common cause of persistent infections [J].
Costerton, JW ;
Stewart, PS ;
Greenberg, EP .
SCIENCE, 1999, 284 (5418) :1318-1322