Improved scanning laser fundus imaging using polarimetry

被引:40
作者
Bueno, Juan M.
Hunter, Jennifer J.
Cookson, Christopher J.
Kisilak, Marsha L.
Campbell, Melanie C. W. [1 ]
机构
[1] Univ Waterloo, Dept Phys & Astron, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Sch Optometry, Waterloo, ON N2L 3G1, Canada
[3] Guelph Waterloo Phys Inst, Waterloo, ON N2L 3G1, Canada
[4] Univ Murcia, Lab Opt, CiOyN, E-30071 Murcia, Spain
关键词
D O I
10.1364/JOSAA.24.001337
中图分类号
O43 [光学];
学科分类号
070207 [光学]; 0803 [光学工程];
摘要
We present a polarimetric technique to improve fundus images that notably simplifies and extends a previous procedure [Opt. Lett. 27, 830 (2002)]. A generator of varying polarization states was incorporated into the illumination path of a confocal scanning laser ophthalmoscope. A series of four images, corresponding to independent incoming polarization states, were recorded. From these images, the spatially resolved elements of the top row of the Mueller matrix were computed. From these elements, images with the highest and lowest quality (according to different image quality metrics) were constructed, some of which provided improved visualization of fundus structures of clinical importance (vessels and optic nerve head). The metric values were better for these constructed images than for the initially recorded images and better than averaged images. Entropy is the metric that is most sensitive to differences in the image quality. Improved visualization of features could aid in the detection, localization, and tracking of ocular disease and may be applicable in other biomedical imaging. (c) 2007 Optical Society of America
引用
收藏
页码:1337 / 1348
页数:12
相关论文
共 54 条
[1]
CONFOCAL FUNDUS IMAGING WITH A SCANNING LASER OPHTHALMOSCOPE IN EYES WITH CATARACT [J].
BECKMAN, C ;
BONDTAYLOR, L ;
LINDBLOM, B ;
SJOSTRAND, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (10) :900-904
[2]
BECKMAN C, 1995, 1995 OSA TECHNICAL D, V1, P106
[3]
Quantitative analysis of the lamina cribrosa in vivo using a scanning laser opthalmoscope [J].
Bhandari, A ;
Fontana, L ;
Fitzke, FW ;
Hitchings, RA .
CURRENT EYE RESEARCH, 1997, 16 (01) :1-8
[4]
Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry [J].
Bowd, Christopher ;
Zangwill, Linda M. ;
Medeiros, Felipe A. ;
Tavares, Ivan M. ;
Hoffmann, Esther M. ;
Bourne, Rupert R. ;
Sample, Pamela A. ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) :2889-2895
[5]
The influence of depolarization and corneal birefringence on ocular polarization [J].
Bueno, JM .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2004, 6 (03) :S91-S99
[6]
Polarimetric high-resolution confocal scanning laser ophthalmoscope [J].
Bueno, JM ;
Vohnsen, B .
VISION RESEARCH, 2005, 45 (28) :3526-3534
[7]
Aberro-polariscope for the human eye [J].
Bueno, JM ;
Berrio, E ;
Artal, P .
OPTICS LETTERS, 2003, 28 (14) :1209-1211
[8]
Polarization properties of the in vitro old human crystalline lens [J].
Bueno, JM ;
Campbell, MCW .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (02) :109-118
[9]
Polarimetry in the human eye using an imaging linear polariscope [J].
Bueno, JM .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2002, 4 (05) :553-561
[10]
Confocal scanning laser ophthalmoscopy improvement by use of Mueller-matrix polarimetry [J].
Bueno, JM ;
Campbell, MCW .
OPTICS LETTERS, 2002, 27 (10) :830-832