Echocardiographic assessment of stentless aortic bioprosthetic valves

被引:10
作者
Bach, DS [1 ]
机构
[1] Univ Michigan, Dept Internal Med, Div Cardiol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1067/mje.2000.105464
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stentless tissue aortic valves are gaining in popularity because of advantages in hemodynamics and durability compared with stented bioprostheses. The absence of a rigid sewing ring and struts makes these valves pliable, and distortion at implantation can result in valve dysfunction. Because the anatomy and implantation techniques of stentless tissue valves are unlike those of mechanical and stented tissue valves, their echocardiographic appearance is unique on both intraoperative and subsequent transthoracic and transesophageal echocardiography. This report describes the echocardiographic appearance of normally functioning stentless tissue heterograft aortic valves as an aid to their intraoperative and subsequent echocardiographic assessment.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 16 条
[1]   Hemodynamics and left ventricular mass regression following implantation of the Toronto SPV stentless porcine valve [J].
Bach, DS ;
David, T ;
Yacoub, M ;
Pepper, J ;
Goldman, B ;
Wood, J ;
Verrier, F ;
Petracek, M ;
Aldrete, V ;
Rosenbloom, M ;
Azar, H ;
Rakowski, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (10) :1214-1219
[2]  
BACH DS, 1999, IN PRESS SEMIN TH S1, V11, P88
[3]   MECHANISM OF EFFICACY OF 2-AMINO OLEIC-ACID FOR INHIBITION OF CALCIFICATION OF GLUTARALDEHYDE-PRETREATED PORCINE BIOPROSTHETIC HEART-VALVES [J].
CHEN, WL ;
SCHOEN, FJ ;
LEVY, RJ .
CIRCULATION, 1994, 90 (01) :323-329
[4]   Left ventricular mass regression early after aortic valve replacement [J].
Christakis, GT ;
Joyner, CD ;
Morgan, CD ;
Fremes, SE ;
Buth, KJ ;
Sever, JY ;
Rao, V ;
Panagiotopoulos, KP ;
Murphy, PM ;
Goldman, BS .
ANNALS OF THORACIC SURGERY, 1996, 62 (04) :1084-1089
[5]  
David TE, 1998, J HEART VALVE DIS, V7, P250
[6]  
DORY DB, 1999, IN PRESS SEMIN TH S1, V11, P35
[7]   Hemodynamic features of the freestyle aortic bioprosthesis compared with stented bioprosthesis [J].
Dumesnil, JG ;
LeBlanc, MH ;
Cartier, PC ;
Métras, J ;
Desaulniers, D ;
Doyle, DP ;
Lemieux, MD ;
Raymond, G .
ANNALS OF THORACIC SURGERY, 1998, 66 (06) :S130-S133
[8]   Effects of exercise on Doppler-derived pressure difference, valve resistance, and effective orifice area in different aortic valve prostheses of similar size [J].
Eriksson, MJ ;
Rosfors, S ;
Rådegran, K ;
Brodin, LÅ .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (04) :619-622
[9]   Hemodynamic performance of cryopreserved aortic homograft valves during midterm follow-up [J].
Eriksson, MJ ;
Källner, G ;
Rosfors, S ;
Ivert, T ;
Brodin, LÅ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (04) :1002-1008
[10]   EFFECT OF AOA ON GLUTARALDEHYDE-FIXED BIOPROSTHETIC HEART-VALVE CUSPS AND WALLS - BINDING AND CALCIFICATION STUDIES [J].
GIRARDOT, MN ;
TORRIANNI, M ;
GIRARDOT, JMD .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (02) :76-82