Reliability of high strain ionomeric polymer transducers fabricated using the direct assembly process

被引:37
作者
Akle, Barbar [1 ]
Nawshin, Saila [1 ]
Leo, Donald [1 ]
机构
[1] Virginia Tech, Ctr Intelligent Mat Syst & Struct, Dept Mech Engn, Blacksburg, VA 24061 USA
关键词
Bending strength - Electrodes - Polymeric membranes - Ruthenium compounds - Strain - Voltage control;
D O I
10.1088/0964-1726/16/2/S09
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Ionomeric polymer transducers have received considerable attention in the past several years. These actuators, sometimes referred to as artificial muscles, have the ability to generate large bending strain and moderate stress at low applied voltages. As sensors, ionic polymer transducers generate an electric response due to mechanical strain. Typically, ionic polymer transducers are composed of Nafion-117 membranes with platinum electrodes and are saturated with water diluents. Recently the authors have developed a novel fabrication technique called the direct assembly process (DAP), which allowed improved control of the electrode morphology and composition. The DAP consists of spraying two high surface area metal - ionomer electrodes on a Nafion membrane. The benefits of the DAP process over previous methods is the ability to control the thickness of the electrode, the ability to control the composition of the electrode layer of the transducer, and the ability for it to be used with a wide variety of diluents. In past work we have demonstrated that platinum, ruthenium dioxide, and single-walled carbon nanotubes can be used as electrode material with diluents such as water, formamide, and ionic liquids. In this work we will present a reliability study of transducers fabricated using the DAP. Water-hydrated transducers dehydrate and stop moving within 5 min while operating in air under the application of +/- 2 V. Ionic liquid based transducers are demonstrated to operate in air for over 400 000 cycles with little loss in performance, and are reliable up to 1 million cycles with a performance loss of less than 43%. The main source of degradation is the adhesion of the conductive surface to the high surface area electrode. This is enhanced in this study by using a PUU linking polymer that has good adhesion properties to gold. Large voltage and large strain are proven to decrease the life of the transducer. Formamide based samples are stable for 3 days under a 1 V actuation signal, while they are only reliable for 3 - 4 h under a 2 V actuation signal. Solvent evaporation is the main reason for degradation in formamide samples and it is increased at 2 V, indicating some electrochemical activity at such high voltages. Finally the initial drop in performance and the fluctuation in the generated strain are shown to be due to the loss of humidity absorbed from ambient air and the fluctuation in this ambient humidity, respectively.
引用
收藏
页码:S256 / S261
页数:6
相关论文
共 11 条
[1]   High-strain ionomeric-ionic liquid electroactive actuators [J].
Akle, BJ ;
Bennett, MD ;
Leo, DJ .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 126 (01) :173-181
[2]   Correlation of capacitance and actuation in ionomeric polymer transducers [J].
Akle, BJ ;
Leo, DJ ;
Hickner, MA ;
Mcgrath, JE .
JOURNAL OF MATERIALS SCIENCE, 2005, 40 (14) :3715-3724
[3]  
AKLE BJ, 2007, IN PRESS J MAT SCI
[4]  
BENNETT M, 2007, SENSOR ACTUAT A-PHYS, V115, P7
[5]   Hydroxylamine seeding of colloidal Au nanoparticles in solution and on surfaces [J].
Brown, KR ;
Natan, MJ .
LANGMUIR, 1998, 14 (04) :726-728
[6]  
Kim SH, 2003, FOOD SCI BIOTECHNOL, V12, P79
[7]  
OGURO K, 1992, J MICROMACHINE SOC, V5, P27
[8]  
Sadeghipour K., 1992, SMART MATER STRUCT, V1, P3445
[9]   Ionic polymer-metal composites (IPMCs) as biomimetic sensors, actuators and artificial muscles - a review [J].
Shahinpoor, M ;
Bar-Cohen, Y ;
Simpson, JO ;
Smith, J .
SMART MATERIALS & STRUCTURES, 1998, 7 (06) :R15-R30
[10]  
SUPRIYA L, 2007, UNPUB SMART MAT STRU