Bioimpedance norms for the hemodialysis population

被引:109
作者
Chertow, GM
Lazarus, JM
Lew, NL
Ma, LH
Lowrie, EG
机构
[1] HARVARD UNIV, SCH MED,BRIGHAM & WOMENS HOSP,DEPT MED,RENAL DIV, BOSTON, MA USA
[2] HARVARD UNIV, SCH MED,BRIGHAM & WOMENS HOSP,DEPT SURG, METAB SUPPORT SERV, BOSTON, MA USA
[3] FRESENIUS MED CARE NA, LEXINGTON, MA USA
关键词
bioimpedance norms; hemodialysis; nutritional status in hemodialysis; body composition;
D O I
10.1038/ki.1997.493
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
More than 3,000 hemodialysis patients were examined with single-frequency bioelectrical impedance analysis (BIA). Distributions of resistance, reactance, phase angle (PA), and estimates of total body water (TBW) and body cell mass (BCM) by BIA were determined, and compared with traditional laboratory markers of nutritional status. Bioimpedance parameters and body composition estimates differed significantly by age, sex, race, and diabetic status. PA and BCM correlated directly with serum creatinine, albumin, and prealbumin concentrations. Population-based norms for bioimpedance parameters and estimates of body composition are provided.
引用
收藏
页码:1617 / 1621
页数:5
相关论文
共 18 条
[1]  
Acchiardo S R, 1983, Kidney Int Suppl, V16, pS199
[2]   MARKERS FOR SURVIVAL IN DIALYSIS - A 7-YEAR PROSPECTIVE-STUDY [J].
AVRAM, MM ;
MITTMAN, N ;
BONOMINI, L ;
CHATTOPADHYAY, J ;
FEIN, P .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1995, 26 (01) :209-219
[3]  
CHERTOW GM, 1995, J AM SOC NEPHROL, V6, P75
[4]   CANADIAN HEMODIALYSIS MORBIDITY STUDY [J].
CHURCHILL, DN ;
TAYLOR, DW ;
COOK, RJ ;
LAPLANTE, P ;
BARRE, P ;
CARTIER, P ;
FAY, WP ;
GOLDSTEIN, MB ;
JINDAL, K ;
MANDIN, H ;
MCKENZIE, JK ;
MUIRHEAD, N ;
PARFREY, PS ;
POSEN, GA ;
SLAUGHTER, D ;
ULAN, RA ;
WERB, R .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1992, 19 (03) :214-234
[5]   UREA INDEX AND OTHER PREDICTORS OF HEMODIALYSIS PATIENT SURVIVAL [J].
COLLINS, AJ ;
MA, JZ ;
UMEN, A ;
KESHAVIAH, P .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 23 (02) :272-282
[6]  
de Fraiteur M, 1978, Acta Orthop Belg, V44, P651
[7]  
DUMLER F, 1992, MINER ELECTROL METAB, V18, P284
[8]   BIOIMPEDANCE ANALYSIS OF TOTAL-BODY WATER IN HEMODIALYSIS-PATIENTS [J].
HO, LT ;
KUSHNER, RF ;
SCHOELLER, DA ;
GUDIVAKA, R ;
SPIEGEL, DM .
KIDNEY INTERNATIONAL, 1994, 46 (05) :1438-1442
[9]   VOLUME STATUS AND BODY-COMPOSITION OF CHRONIC DIALYSIS PATIENTS - UTILITY OF BIOELECTRIC IMPEDANCE PLETHYSMOGRAPHY [J].
KURTIN, PS ;
SHAPIRO, AC ;
TOMITA, H ;
RAIZMAN, D .
AMERICAN JOURNAL OF NEPHROLOGY, 1990, 10 (05) :363-367
[10]   DEATH RISK IN HEMODIALYSIS-PATIENTS - THE PREDICTIVE VALUE OF COMMONLY MEASURED VARIABLES AND AN EVALUATION OF DEATH RATE DIFFERENCES BETWEEN FACILITIES [J].
LOWRIE, EG ;
LEW, NL .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 15 (05) :458-482