A system for determination of manganese, after preconcentration with 3% (w/w) 1-(2-pyridylazo)-2-naphthol (PAN), adsorbed on microcrystalline naphthalene is proposed. An amount of 200 mg of this complexing mixture is placed in a glass column and conditioned with a NH4Cl/NH4OH buffer solution (pH 9.5). The aqueous sample, containing manganese, is treated with an ammonium tartrate solution, then with a hydroxylammonium chloride solution and, finally, with a buffer solution. The resulting solution is passed through the column containing microcrystalline naphthalene modified with 1-(2-pyridylazo)-2-naphthol (PAN) where Mn(II) is retained. The column is first washed with deionized water and then with 10.0 ml of dimethylformamide to dissolve the Mn(II)-PAN/naphthalene complex. Manganese is determined by air-acetylene flame atomic absorption spectrometry. About 1 mu g of manganese can be concentrated from 200 ml of aqueous sample, allowing a preconcentration factor of 20, a limit of quantification of 5 ng ml(-1) and R.S.D. of 3.8%. The accuracy was ascertained using certified reference materials, including samples of urine and glass. Water samples were also analysed and the results are in good agreement with those obtained by graphite furnace atomic absorption spectrometry. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1252 / 1256
页数:5
相关论文
共 28 条
[1]   On-line preconcentration of some rare earth elements in water samples using C18-cartridge modified with 1-(2-pyridylazo) 2-naphtol (PAN) prior to simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES) [J].
Bahramifar, N ;
Yamini, Y .
ANALYTICA CHIMICA ACTA, 2005, 540 (02) :325-332
[2]  
Behpour M, 2005, ACTA CHIM SLOV, V52, P323
[3]   Use of Amberlite XAD-2 loaded with 1-(2-pyridylazo)-2-naphthol as a preconcentration system for river water prior to determination of Cu2+, Cd2+ and Pb2+ by flame atomic absorption spectroscopy [J].
Bermejo-Barrera, P ;
Nancy, MA ;
Cristina, DL ;
Adela, BB .
MICROCHIMICA ACTA, 2003, 142 (1-2) :101-108
[4]   Determination of cadmium by flame-atomic absorption Spectrometry after preconcentration on silica gel modified with cupferron [J].
Bortoleto, GG ;
Macarovscha, GT ;
Cadore, S .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (02) :313-317
[5]  
BRAUN T, 1980, ANAL CHIM ACTA, V119, P639
[6]   Flame atomic absorption determination of cobalt in water after extraction of its morpholinedithiocarbamate complex [J].
Cadore, S ;
Goi, RD ;
Baccan, N .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (05) :957-962
[7]   1-(2-PYRIDYLAZO)-2-NAPHTHOL AS A POSSIBLE ANALYTICAL REAGENT [J].
CHENG, KL ;
BRAY, RH .
ANALYTICAL CHEMISTRY, 1955, 27 (05) :782-785
[8]   DETERMINATION OF MANGANESE IN HIGH-PURITY NIOBIUM TANTALUM MOLYBDENUM AND TUNGSTEN METALS WITH PAN [J].
DONALDSO.EM ;
INMAN, WR .
TALANTA, 1966, 13 (03) :489-&
[9]   SOLID-LIQUID SEPARATION AFTER LIQUID-LIQUID EXTRACTION [J].
FUJINAGA, T ;
KUWAMOTO, T ;
NAKAYAMA, E .
TALANTA, 1969, 16 (08) :1225-&
[10]  
GIRAUDI G, 1984, ANN CHIM-ROME, V74, P307