Investigation of bacterial chemotaxis in flow-based microfluidic devices

被引:52
作者
Englert, Derek L. [1 ]
Manson, Michael D. [2 ,3 ]
Jayaraman, Arul [1 ,4 ]
机构
[1] Texas A&M Univ, McFerrin Dept Chem Engn, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Biol, College Stn, TX 77843 USA
[3] Texas A&M Univ, Dept Biochem & Biophys, College Stn, TX 77843 USA
[4] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
基金
美国国家科学基金会;
关键词
ESCHERICHIA-COLI; GRADIENTS;
D O I
10.1038/nprot.2010.18
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The plug-in-pond and capillary assays are convenient methods for measuring attractant and repellent bacterial chemotaxis. However, these assays do not provide quantitative information on the extent of migration and are not well-suited for investigating repellent taxis. Here, we describe a protocol for a flow-based microfluidic system (mu Flow) to quantitatively investigate chemotaxis in response to concentration gradients of attractants and repellents. The mu Flow device uses diffusive mixing to generate concentration gradients that are stable throughout the chemotaxis chamber and for the duration of the experiment. The gradients may be of any desired absolute concentration and gradient strength. GFP-expressing bacteria immediately encounter a stable concentration gradient when they enter the chemotaxis chamber, and the migration in response to the gradient is monitored by microscopy. The effects of different parameters that influence the extent of migration in the mu Flow device-preparation of the motile bacterial population preparation, strength of the concentration gradient and duration of exposure to the gradient-are discussed in the context of repellent taxis of chemotactically wild-type Escherichia coli cells in a gradient of NiSO4. Fabrication of the microfluidic device takes 1 d while preparing motile cells and carrying out the chemotaxis experiment takes 4-6 h to complete.
引用
收藏
页码:864 / 872
页数:9
相关论文
共 17 条
[1]   METHOD FOR MEASURING CHEMOTAXIS AND USE OF METHOD TO DETERMINE OPTIMUM CONDITIONS FOR CHEMOTAXIS BY ESCHERICHIA-COLI [J].
ADLER, J .
JOURNAL OF GENERAL MICROBIOLOGY, 1973, 74 (JAN) :77-91
[2]  
BROWN D A, 1974, Proceedings of the National Academy of Sciences of the United States of America, V71, P1388, DOI 10.1073/pnas.71.4.1388
[3]   A hydrogel-based microfluidic device for the studies of directed cell migration [J].
Cheng, Shing-Yi ;
Heilman, Steven ;
Wasserman, Max ;
Archer, Shivaun ;
Shuler, Michael L. ;
Wu, Mingming .
LAB ON A CHIP, 2007, 7 (06) :763-769
[4]   A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis [J].
Diao, JP ;
Young, L ;
Kim, S ;
Fogarty, EA ;
Heilman, SM ;
Zhou, P ;
Shuler, ML ;
Wu, MM ;
DeLisa, MP .
LAB ON A CHIP, 2006, 6 (03) :381-388
[5]  
Englert DL, 2009, METHODS MOL BIOL, V571, P1, DOI 10.1007/978-1-60761-198-1_1
[6]   Flow-Based Microfluidic Device for Quantifying Bacterial Chemotaxis in Stable, Competing Gradients [J].
Englert, Derek L. ;
Manson, Michael D. ;
Jayaraman, Arul .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2009, 75 (13) :4557-4564
[7]  
ENGLERT DL, J BACTERIOL IN PRESS
[8]   Assessment of GFP fluorescence in cells of Streptococcus gordonii under conditions of low pH and low oxygen concentration [J].
Hansen, MC ;
Palmer, RJ ;
Udsen, C ;
White, DC ;
Molin, S .
MICROBIOLOGY-SGM, 2001, 147 :1383-1391
[9]   ESCHERICHIA-COLI MUTANTS DEFECTIVE IN CHEMOTAXIS TOWARD SPECIFIC CHEMICALS [J].
HAZELBAU.GL ;
MESIBOV, RE ;
ADLER, J .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1969, 64 (04) :1300-&
[10]   Neutrophil chemotaxis in linear and complex gradients of interleukin-8 formed in a microfabricated device [J].
Jeon, NL ;
Baskaran, H ;
Dertinger, SKW ;
Whitesides, GM ;
Van de Water, L ;
Toner, M .
NATURE BIOTECHNOLOGY, 2002, 20 (08) :826-830