In vitro evaluation of Er:YAG laser scaling of subgingival calculus in comparison with ultrasonic scaling

被引:103
作者
Aoki, A [1 ]
Miura, M [1 ]
Akiyama, F [1 ]
Nakagawa, N [1 ]
Tanaka, J [1 ]
Oda, S [1 ]
Watanabe, H [1 ]
Ishikawa, I [1 ]
机构
[1] Tokyo Med & Dent Univ, Dept Hard Tissue Engn, Grad Sch, Bunkyo Ku, Tokyo 1138549, Japan
关键词
Er : YAG laser; scaling; subgingival calculus; cementum;
D O I
10.1034/j.1600-0765.2000.035005266.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of the present study was to evaluate the effectiveness of Er:YAG laser scaling and the morphological and histological changes of the laser-scaled root surface in comparison with the effectiveness and root surface changes produced by conventional ultrasonic scaling. Fifty-three periodontally involved human extracted teeth with a band of subgingival calculus were used. The teeth were divided randomly into 2 groups for laser scaling and ultrasonic scaling. Laser irradiation was performed at an energy output of 40 mJ/pulse and 10 pulses/s under water spray, with the probe lip contacted obliquely to the root surface. Ultrasonic scaling was performed at a clinically standard power setting. The time required for scaling, the scaled area and the temperature changes were determined using both methods of treatment. The features of the scaled surfaces were examined by histological and scanning electron microscope (s.e.m.) observations. The Er:YAG laser provided subgingival calculus removal on a level equivalent to that provided by the ultrasonic scaler, without major thermal elevation. Macroscopically, the laser-treated root surface was somewhat rougher than or similar to the ultrasonically scaled root. However, the efficiency of the laser scaling was lower than that of the ultrasonic scaling. In addition, histological examination revealed a thin deeply stained zone on the lased root surface. and s.e.m. analysis revealed a characteristic microroughness on the lased surface. The laser scaling provided a level of calculus removal that was similar to that provided by the ultrasonic scaling. However, the Er:YAG laser produced superficial. structural and thermal microchanges on the root cementum.
引用
收藏
页码:266 / 277
页数:12
相关论文
共 32 条
[1]  
Ando Y, 1996, LASER SURG MED, V19, P190
[2]   Comparison between Er:YAG laser and conventional technique for root caries treatment in vitro [J].
Aoki, A ;
Ishikawa, I ;
Yamada, T ;
Otsuki, M ;
Watanabe, H ;
Tagami, J ;
Ando, Y ;
Yamamoto, H .
JOURNAL OF DENTAL RESEARCH, 1998, 77 (06) :1404-1414
[3]   IN-VITRO STUDIES ON LASER SCALING OF SUBGINGIVAL CALCULUS WITH AN ERBIUM-YAG LASER [J].
AOKI, A ;
ANDO, Y ;
WATANABE, H ;
ISHIKAWA, I .
JOURNAL OF PERIODONTOLOGY, 1994, 65 (12) :1097-1106
[4]   Er:YAG clinical experience in Japan:: Review of scientific investigations [J].
Aoki, A ;
Watanabe, H ;
Ishikawa, I .
LASERS IN DENTISTRY IV, PROCEEDINGS OF, 1998, 3248 :40-45
[5]  
Cohen RE, 1996, J PERIODONTOL, V67, P826
[6]   Dentistry for the 21st century? Erbium:YAG laser for teeth [J].
Cozean, C ;
Arcoria, CJ ;
Pelagalli, J ;
Powell, GL .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (08) :1080-1087
[7]   The effect of working parameters on root substance removal using a piezoelectric ultrasonic scaler in vitro [J].
Flemmig, TF ;
Petersilka, GJ ;
Mehl, A ;
Hickel, R ;
Klaiber, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1998, 25 (02) :158-163
[8]   Scanning electron microscopic study of the effects of Er:YAG laser on root cementum [J].
Fujii, T ;
Baehni, PC ;
Kawai, O ;
Kawakami, T ;
Matsuda, K ;
Kowashi, Y .
JOURNAL OF PERIODONTOLOGY, 1998, 69 (11) :1283-1290
[9]   SUPERFICIAL CEMENTAL CURETTAGE - ITS EFFICACY IN PROMOTING IMPROVED CELLULAR ATTACHMENT ON HUMAN ROOT SURFACES PREVIOUSLY DAMAGED BY PERIODONTITIS [J].
FUKAZAWA, E ;
NISHIMURA, K .
JOURNAL OF PERIODONTOLOGY, 1994, 65 (02) :168-176
[10]  
Fukuda M., 1994, JPN J CONSERV DENT, V37, P711