Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component - A retrospective analysis of fifty-six cases

被引:85
作者
Goetz, DD
Capello, WN
Callaghan, JJ
Brown, TD
Johnston, RC
机构
[1] Univ Iowa, Coll Med, Iowa City, IA USA
[2] Iowa Methodist Med Ctr, Des Moines, IA USA
[3] Indiana Univ, Med Ctr, Sch Med, Dept Orthopaed Surg, Indianapolis, IN 46202 USA
关键词
D O I
10.2106/00004623-199804000-00006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fifty-six constrained acetabular components were placed, between April 1988 and February 1993, in fifty-five patients who had had recurrent dislocations (average, six dislocations; range, two to twenty dislocations) of the femoral component after a previous total hip arthroplasty, All patients had additional factors contributing to the instability of the implant, including absence or disruption of the abductor mechanism, poor health, mental retardation, confusion, and Alzheimer disease. One patient was lost to follow-up. The remaining patients mere followed clinically for a minimum of three years (average, sixty-four months; range, thirty-seven to ninety-seven months) or until the time of death. During the follow-up interval, only two (4 per cent) of the fifty-five patients had a subsequent dislocation. The use of this type of component should be considered for patients who have recurrent dislocation if other treatment modalities are unlikely to be effective.
引用
收藏
页码:502 / 509
页数:8
相关论文
共 14 条
[1]  
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[2]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[3]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[4]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[5]   FEMORAL COMPONENT LOOSENING USING CONTEMPORARY TECHNIQUES OF FEMORAL CEMENT FIXATION [J].
HARRIS, WH ;
MCCARTHY, JC ;
ONEILL, DA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1063-1067
[6]   LOOSENING OF THE FEMORAL COMPONENT AFTER USE OF THE MEDULLARY-PLUG CEMENTING TECHNIQUE - FOLLOW-UP NOTE WITH A MINIMUM 5-YEAR FOLLOW-UP [J].
HARRIS, WH ;
MCGANN, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1064-1066
[7]   CLINICAL AND RADIOGRAPHIC EVALUATION OF TOTAL HIP-REPLACEMENT - A STANDARD SYSTEM OF TERMINOLOGY FOR REPORTING RESULTS [J].
JOHNSTON, RC ;
FITZGERALD, RH ;
HARRIS, WH ;
POSS, R ;
MULLER, ME ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (02) :161-168
[8]  
Kaplan S J, 1987, J Arthroplasty, V2, P119, DOI 10.1016/S0883-5403(87)80018-9
[9]   Long-term results of revision total hip arthroplasty with improved cementing technique [J].
Katz, RP ;
Callaghan, JJ ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :322-326
[10]  
LOUDON JR, 1980, J BONE JOINT SURG BR, V62, P450