Neutron spectra and dosimetric features around an 18 MV Linac accelerator

被引:68
作者
Barquero, R
Mendez, R
Vega-Carrillo, HR
Iñiguez, MP
Edwards, TM
机构
[1] Univ Valladolid, Hosp Rio Hortega, Valladolid 47014, Spain
[2] Univ Valladolid, Dept Fis Teor Atom Mol & Nucl, Valladolid 47014, Spain
[3] UAs Estudios Nucl, Zacatecas 98000, Zac, Mexico
来源
HEALTH PHYSICS | 2005年 / 88卷 / 01期
关键词
spectrometry; neutron; accelerators; neutron dosimetry; Monte Carlo;
D O I
10.1097/01.HP.0000142500.32040.ac
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Using the difference between responses to neutrons of TLD-600 and TLD-700, three experimental devices were constructed and arranged to measure thermal neutron fluences, neutron spectra, and neutron doses inside the treatment room of a radiotherapy 18 MV Linear electron accelerator (Linac). Thermal neutron fluences were measured with TLD600/TLD-700 pairs arranged in both a bare and a cadmium (Cd) foil covered methacrylate box. Neutron spectra were measured in 26 energy bins by introducing pairs of TLD-600/ TLD-700 in air and into the middle of five polyethylene spheres with diameters of 3, 5, 8, 10, and 12 inches. A PC version of the BUNKI code was used to unfold the six measurements in each sphere to obtain the 26 energy bins. Neutron and photon doses were measured by introducing pairs of TLD-600/TLD-700 into the middle of a single 25-cm-diameter paraffin sphere. The three required neutron calibrations were carried out at the Nuclear Technology Laboratory of the Polytechnique University of Madrid (UPM), using an Am-241-Be neutron source with an alpha activity of 111 GBq and a yield of 6.6 x 10(6) neutrons s(-1). Three devices were needed for the necessary calibrations: a BF3 counter for the thermal neutron fluence calibration, a LUDLUM 42-5 Bonner spectrometer with five 0.95 g cm(-3) polyethylene spheres with a LiI(Eu) 4 x 4 mm(2) scintillation counter for the neutron spectrometer calibration and a NEMO 9140 remmeter for the paraffin remmeter calibration. The Monte Carlo code MCNP 4C has been used in two ways: to calculate the neutron kerma contribution to two TLDs (type 600 and 700) both in air and inside the paraffin sphere, and to determine the neutron spectra at those Linac room zones where the neutron spectra were measured. Thermal neutron fluences of 2.9 x 10(4) +/- 8.6 x 10(3) cm(-2) s(-1), measured around the Linac head plane, and 2.3 x 10(4 +/-) 2.3 x 10(3) cm(-2) s(-1), measured at the patient couch plane, are in agreement with previous independent measurements from other authors. The calculated and measured neutron spectra obtained in the treatment room showed three distinct regions: a peak around 0.1 MeV, a flat epithermal region and a thermal region with values similar to those mentioned above. Patient dose equivalents of 0.5 mSv and 5 mSv from neutrons and photons, respectively, were obtained per treatment Gray.
引用
收藏
页码:48 / 58
页数:11
相关论文
共 30 条
[1]   Neutron transport in a clinical linear accelerator bunker: comparison of materials for reducing the photo-neutron dose at the maze entrance [J].
Baker, CR ;
Thomas, SJ .
RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) :633-634
[2]  
BARLETT DT, 1999, RADIAT PROT DOSIM, V86, P107
[3]  
BARQUERO R, 2002, THESIS U VALLADOLID
[4]   Use of bubble detectors to measure neutron contamination of a medical accelerator photon beam [J].
Bourgois, L ;
Delacroix, D ;
Ostrowsky, A .
RADIATION PROTECTION DOSIMETRY, 1997, 74 (04) :239-246
[5]  
BRACKENBUSH LW, 1984, P 17 MIDY TOP S HLTH
[6]  
Briesmeister J.F., 2000, LA13709M LOS AL NAT
[7]   Evaluation of neutron dose in the maze of medical electron accelerators [J].
Carinou, E ;
Kamenopoulou, V ;
Stamatelatos, IE .
MEDICAL PHYSICS, 1999, 26 (12) :2520-2525
[8]   In vivo neutron dosimetry during high-energy bremsstrahlung radiotherapy [J].
D'Errico, F ;
Nath, R ;
Silvano, G ;
Tana, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (05) :1185-1192
[9]   Characteristics of the neutron field of the facility at DIN-UPM [J].
Gallego, E ;
Lorente, A ;
Vega-Carrillo, HR .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :73-79
[10]   THE RESPONSE OF BONNER SPHERES TO NEUTRONS FROM THERMAL ENERGIES TO 17.3 MEV [J].
HERTEL, NE ;
DAVIDSON, JW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 238 (2-3) :509-516