The effect of subcrestal placement of the polished surface of ITI(R) implants on marginal soft and hard tissues

被引:217
作者
Hammerle, CHF
Bragger, U
Burgin, W
Lang, NP
机构
[1] University of Bern, School of Dental Medcine, Dept. Periodontol./Fixed P., Bern
[2] University of Bern, School of Dental Medicine
关键词
dental implantation; osseointegrated; jaw; alveolar bone loss; human; wound healing;
D O I
10.1034/j.1600-0501.1996.070204.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In order to achieve esthetically more satisfying results, it has been proposed to place ITI implants with their border between the rough and smooth surfaces below the level of the alveolar crest, thereby obtaining a submucosally located implant shoulder following healing. The aim of the present experimental study was to clinically and radiographically evaluate the tissue response to the placement of one-stage transmucosal implants with the border between the rough and the smooth surfaces sunk by 1 mm into a subcrestal location. 11 patients underwent comprehensive dental care including the placement of 2 implants of the ITI Dental Implant System(TM) in the same quadrant (test and control). Randomly assigned control implants were placed according to the manufacturer's instructions, i.e. the border between the rough titanium plasma-sprayed and the smooth polished surfaces precisely at the alveolar crest. At the test implants the apical border of the polished surface was placed similar to 1 mm below the alveolar crest. Probing bone levels were assessed at implant placement (baseline), 4 and 12 months later. Modified plaque and modified gingival indices were recorded at 1, 2, 3, 4 and 12 months. Clinical probing depth and ''attachment'' levels were measured at 4 and 12 months. All parameters were assessed at 6 sites around each implant. The mean for each implant was calculated and used for analysis. The Wilcoxon matched pairs signed rank test and the Student t-test were applied to detect differences over time and between the test and control implants. At baseline, a mean difference in probing bone level of -0.86 mm (SD 0.43 mm, p<0.05) was found between test and control implants with the test implants being placed more deeply. Both test and control implants lost a significant amount of clinical bone height during the first 4 months (test 1.16 mm, p<0.05; control 0.58 mm, p<0.05). However, only the test implants significantly lost clinical bone height from 4-12 months (test 1.04 mm, p<0.05; control 0.45 mm, p=0.08). Overall, the test implants lost 2.26 mm and the control implants 1.02 mm of bone height during the first year of service. On the average, the test implants demonstrated a bone level 0.38 mm lower than the controls at 12 months. Except for the modified gingival index at 4 months (mean difference 0.21, SD 0.19, p<0.05), no clinical parameters yielded significant differences between test and control implants at any time. It is concluded that in addition to the crestal bone resorption occurring at implants placed under standard conditions, the bone adjacent to the polished surface of more deeply placed ITI implants is also lost over time. Form a biological point of view, the placement of the border between the rough and the smooth surfaces into a subcrestal location should not be recommended. (C) Munksgaard, 1996.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 39 条
[1]   MARGINAL TISSUE-REACTIONS AT OSSEOINTEGRATED TITANIUM FIXTURES .1. A 3-YEAR LONGITUDINAL PROSPECTIVE-STUDY [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI ;
LINDHE, J ;
ERIKSSON, B ;
SBORDONE, L .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1986, 15 (01) :39-52
[2]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[3]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[4]   PREDICTABLE CRESTAL BONE REMODELING AROUND 2 POROUS-COATED TITANIUM-ALLOY DENTAL IMPLANT DESIGNS - A RADIOGRAPHIC STUDY IN DOGS [J].
ALSAYYED, A ;
DEPORTER, DA ;
PILLIAR, RM ;
WATSON, PA ;
PHAROAH, M ;
BERHANE, K ;
CARTER, S .
CLINICAL ORAL IMPLANTS RESEARCH, 1994, 5 (03) :131-141
[5]   The soft tissue barrier at implants and teeth [J].
Berglundh, T. ;
Lindhe, J. ;
Ericsson, I. ;
Marinello, C. P. ;
Liljenberg, B. ;
Thomsen, P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1991, 2 (02) :81-90
[6]   Fixed reconstructions in partially edentulous patients using two-part ITI implants (Bonefit (R)) as abutments Treatment planning, indications and prosthetic aspects [J].
Braegger, U. ;
Haemmerle, C. ;
Weber, H-P .
CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) :41-49
[7]  
BRAGGER U, 1991, International Journal of Oral and Maxillofacial Implants, V6, P160
[8]   SURGICAL LENGTHENING OF THE CLINICAL CROWN [J].
BRAGGER, U ;
LAUCHENAUER, D ;
LANG, NP .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (01) :58-63
[9]  
Bragger U, 2000, PERIODONTOL 2000, V87- 97
[10]   Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants [J].
Buser, D. ;
Weber, H-P ;
Lang, N. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) :33-40