Development of a graphite low-temperature plasma source with dual-mode in-source fragmentation for ambient mass spectrometry

被引:31
作者
Almasian, Mohammad Reza [1 ]
Yang, Chengdui [1 ]
Xing, Zhi [1 ]
Zhang, Sichun [1 ]
Zhang, Xinrong [1 ]
机构
[1] Tsinghua Univ, Dept Chem, Key Lab Atom & Mol Nanosci, Educ Minist, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
DIELECTRIC BARRIER DISCHARGE; ION-SOURCE; DESORPTION; WATER; SORBENTS; SURFACES; SE; SB;
D O I
10.1002/rcm.4444
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new low-temperature plasma (LTP), based on dielectric barrier discharge (DBD), has been developed as an alternative ionization source for ambient mass spectrometry. For organic samples, the source is able to produce two different fragmentation patterns which are selectable by an electrical switch. The two source modes are different only in the second electrodes: in configuration (A), bar-plate and in configuration (B), coaxial bar cylinder shapes are used. A disposable graphite probe is used as the first electrode, the same in both configurations, and a copper foil is used as the second electrode. The ionization source is applicable to gas and liquid samples, without any change being necessary in its design. Under optimal conditions, to take ethylbenzene as an example, a detection limit of less than 25 ng was obtained and a relative standard deviation (RSD) of 13.36% has been demonstrated for 50 ng of ethylbenzene (n = 11). We have found several interesting differences in the mass spectra of the tested volatile organic compounds (VOCs) in the two modes, which might be applicable in identification studies. We have investigated the effect of variation of the first electrode material and the second electrode length in mode B. Moreover, in this design the graphite electrode is capable of acting as a sample adsorbent, which is a new sampling method for LTP mass spectrometry (MS). This capability was investigated by adsorption of the selected VOCs onto the surface of the graphite electrode in a headspace solid-phase microextraction (SPME) system, and direct desorption and ionization of the samples by LTPMS. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:742 / 748
页数:7
相关论文
共 39 条
[1]   Gas-phase fragmentation of peptides by MALDI in-source decay with limited amide hydrogen (1H/2H) scrambling [J].
Bache, Nicolai ;
Rand, Kasper D. ;
Roepstorff, Peter ;
Jorgensen, Thomas J. D. .
ANALYTICAL CHEMISTRY, 2008, 80 (16) :6431-6435
[2]   Desorption electrospray ionisation mass spectrometric analysis of chemical warfare agents from solid-phase microextraction fibers [J].
D'Agostino, Paul A. ;
Chenier, Claude L. ;
Hancock, James R. ;
Lepage, Carmela R. Jackson .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (04) :543-549
[3]  
de Hoffmann E., 2007, Mass Spectrometry-Priniples and Applications, V3rd
[4]   Adsorbent materials commonly used in air analysis for adsorptive enrichment and thermal desorption of volatile organic compounds [J].
Dettmer, K ;
Engewald, W .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :490-500
[5]   Modified pencil lead as a new fiber for solid-phase microextraction [J].
Djozan, D ;
Assadi, Y .
CHROMATOGRAPHIA, 2004, 60 (5-6) :313-317
[6]  
Fridman A., 2008, PLASMA CHEM
[7]   Direct olive oil analysis by low-temperature plasma (LTP) ambient ionization mass spectrometry [J].
Garcia-Reyes, Juan F. ;
Mazzoti, Fabio ;
Harper, Jason D. ;
Charipar, Nicholas A. ;
Oradu, Sheran ;
Ouyang, Zheng ;
Sindona, Giovanni ;
Cooks, R. Graham .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) :3057-3062
[8]   Adsorption of water vapour in the solid sorbents used for the sampling of volatile organic compounds [J].
Gawlowski, J ;
Gierczak, T ;
Jezo, A ;
Niedzielski, J .
ANALYST, 1999, 124 (11) :1553-1558
[9]   Low-Temperature Plasma Probe for Ambient Desorption Ionization [J].
Harper, Jason D. ;
Charipar, Nicholas A. ;
Mulligan, Christopher C. ;
Zhang, Xinrong ;
Cooks, R. Graham ;
Ouyang, Zheng .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9097-9104
[10]   Dielectric barrier discharge-induced chemiluminescence: Potential application as GC detector [J].
He, Yihua ;
Lv, Yi ;
Li, Yaming ;
Tang, Huarong ;
Tang, Li ;
Wu, Xi ;
Hou, Xiandeng .
ANALYTICAL CHEMISTRY, 2007, 79 (12) :4674-4680