Objective assessments of medial osteoarthritic knee severity by MRI: new computer software to evaluate femoral condyle contours
被引:4
作者:
Ochiai, Nobuyasu
论文数: 0引用数: 0
h-index: 0
机构:
Chiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, JapanChiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, Japan
Ochiai, Nobuyasu
[1
]
论文数: 引用数:
h-index:
机构:
Sasho, Takahisa
[1
]
Tahara, Masamichi
论文数: 0引用数: 0
h-index: 0
机构:
Chiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, JapanChiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, Japan
Tahara, Masamichi
[1
]
Watanabe, Atsuya
论文数: 0引用数: 0
h-index: 0
机构:
Teikyo Univ, Ichihara Hosp, Dept Orthopaed Surg, Chiba, JapanChiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, Japan
Watanabe, Atsuya
[2
]
Matsuki, Kei
论文数: 0引用数: 0
h-index: 0
机构:
Chiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, JapanChiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, Japan
Matsuki, Kei
[1
]
Yamaguchi, Satoshi
论文数: 0引用数: 0
h-index: 0
机构:
Chiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, JapanChiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, Japan
Yamaguchi, Satoshi
[1
]
论文数: 引用数:
h-index:
机构:
Miyake, Yoichi
[3
]
论文数: 引用数:
h-index:
机构:
Nakaguchi, Toshiya
[3
]
论文数: 引用数:
h-index:
机构:
Wada, Yuichi
[2
]
Moriya, Hideshige
论文数: 0引用数: 0
h-index: 0
机构:
Chiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, JapanChiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, Japan
Moriya, Hideshige
[1
]
机构:
[1] Chiba Univ, Grad Sch Med, Dept Orthoped Surg, Chuo Ku, Chiba 2608670, Japan
[2] Teikyo Univ, Ichihara Hosp, Dept Orthopaed Surg, Chiba, Japan
[3] Chiba Univ, Res Ctr Frontier Med Engn, Chiba 2608670, Japan
An irregular contour of the medial femoral condyle (MFC) on magnetic resonance imaging (MRI) appears to indicate the severity of medial-type knee osteoarthritis (OA). The purpose of this study was to establish a system to enable objective assessments of OA knee severity using newly developed software that semi-automatically measures irregularity of the MFC. (1) We evaluated 48 patients aged 50-83 years with 55 knees of medial-type OA. The following scores were recorded: Lysholm score, visual analogue scale (VAS) and the Japanese Knee Osteoarthritis Measure (JKOM). MFC irregularity was automatically calculated by newly programmed computer software. Four parameters for condyle irregularity were calculated: (a) the average thickness of the contour (ATC), (b) the ratio of the upper surface length to the lower surface length of the contour (RUL), (c) average squared thickness of the contour (ASTC) and (d) standard deviation of the contour thickness (SDC). (2) Nine knees that underwent total knee arthroplasty were further analysed histopathologically and compared with irregularity score. Statistically, the RUL and SDC were significantly correlated with the Lysholm score, VAS and JKOM, with good reliability. Histological examinations showed that an irregular contour reflected the density of cystic lesions formed in subchondral bone. An irregularity of MFC on MRI is correlated with OA disease severity clinically and histopathologically. The new computer software is useful to objectively assess OA disease severity.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 28 条
[1]
Akai M, 2005, J RHEUMATOL, V32, P1524
[2]
Boegard T, 1998, ANN RHEUM DIS, V57, P401, DOI 10.1136/ard.57.7.401