Plasma-source mass spectrometry for speciation analysis: state-of-the-art

被引:37
作者
Ray, SJ [1 ]
Andrade, F [1 ]
Gamez, G [1 ]
McClenathan, D [1 ]
Rogers, D [1 ]
Schilling, G [1 ]
Wetzel, W [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
elemental speciation; tunable ionization sources; time-of-flight mass spectrometry; electrospray ionization mass spectrometry;
D O I
10.1016/j.chroma.2004.07.107
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Current and emerging capabilities of plasma-source mass spectrometry (PS-MS) as it is employed for elemental speciation analysis are reviewed. Fundamental concepts and their advantageous aspects, experimental conditions, and analytical performance are described and illustrated by recent examples from the literature. Novel instrumentation, techniques, and strategies for inductively-coupled plasma mass spectrometry (ICP-MS), microwave-induced plasma (MIP) mass spectrometry, glow-discharge (GD) mass spectrometry, and electrospray ionization (ESI), among others, are described. The use of ionization sources that provide tunable ionization, others that can be modulated between different sets of operating conditions, and others used in parallel is also examined. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 34
页数:32
相关论文
共 278 条
[1]   ELEMENTAL SPECIATION MEASUREMENTS WITH ELECTROSPRAY MASS-SPECTROMETRY - AN ASSESSMENT [J].
AGNES, GR ;
STEWART, II ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (11) :1347-1359
[2]   EFFECT OF OPERATING PARAMETERS ON ANALYTE SIGNALS IN ELEMENTAL ELECTROSPRAY MASS-SPECTROMETRY [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1995, 49 (03) :324-334
[3]   Inductively coupled plasma mass spectrometry to identify protein drug targets from whole cell systems [J].
Allardyce, CS ;
Dyson, PJ ;
Abou-Shakra, FR ;
Birtwistle, H ;
Coffey, J .
CHEMICAL COMMUNICATIONS, 2001, (24) :2708-2709
[4]  
Amad MH, 2000, J MASS SPECTROM, V35, P784, DOI 10.1002/1096-9888(200007)35:7<784::AID-JMS17>3.0.CO
[5]  
2-Q
[6]   Kinetic energy dependence of ion-molecule reactions: Guided ion beams and threshold measurements [J].
Armentrout, PB .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 200 (1-3) :219-241
[7]  
ASANO K G, 1990, Spectroscopy (Amsterdam), V8, P191
[8]   Comparison of three coupled gas chromatographic detectors (MS, MIP-AES, ICP-TOFMS) for organolead speciation analysis [J].
Baena, JR ;
Gallego, M ;
Valcárcel, M ;
Leenaers, J ;
Adams, FC .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3927-3934
[10]   Generation of a square wave inductively coupled plasma scanning mass spectrometry signal using electrothermal vaporization sample introduction [J].
Balsanek, WJ ;
Venable, JD ;
Holcombe, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) :59-64