Monte Carlo dose calculations and radiobiological modelling: analysis of the effect of the statistical noise of the dose distribution on the probability of tumour control

被引:29
作者
Buffa, FM [1 ]
Nahum, AE [1 ]
机构
[1] Canc Res Inst & Royal Marsden NHS Trust, Joint Dept Phys, London SW3 6JJ, England
关键词
D O I
10.1088/0031-9155/45/10/318
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work is to investigate the influence of the statistical fluctuations of Monte Carlo (MC) dose distributions on the dose volume histograms (DVHs) and radiobiological models, in particular the Poisson model for tumour control probability (tcp). The MC matrix is characterized by a mean dose in each scoring voxel, d, and a statistical error on the mean dose, sigma(d); whilst the quantities d and sigma(d) depend on many statistical and physical parameters, here we consider only their dependence on the phantom voxel size and the number of histories from the radiation source. Dose distributions from high-energy photon beams have been analysed. It has been found that the DVH broadens when increasing the statistical noise of the dose distribution, and the tcp calculation systematically underestimates the real tumour control value, defined here as the value of tumour control when the statistical error of the dose distribution tends to zero. When increasing the number of energy deposition events, either by increasing the voxel dimensions or increasing the number of histories from the source, the DVH broadening decreases and tcp converges to the 'correct' value. It is shown that the underestimation of the tcp due to the noise in the dose distribution depends on the degree of heterogeneity of the radiobiological parameters over the population; in particular this error decreases with increasing the biological heterogeneity, whereas it becomes significant in the hypothesis of a radiosensitivity assay for single patients, or for subgroups of patients. It has been found, for example, that when the voxel dimension is changed from a cube with sides of 0.5 cm to a cube with sides of 0.25 cm (with a fixed number of histories of 10(8) from the source), the systematic error in the tcp calculation is about 75% in the homogeneous hypothesis, and it decreases to a minimum value of about 15% in a case of high radiobiological heterogeneity. The possibility of using the error on the rep to decide how many histories to run for a given voxel size is also discussed.
引用
收藏
页码:3009 / 3023
页数:15
相关论文
共 20 条
[1]   PHYSICAL AND BIOLOGIC ASPECTS ON THE OPTIMUM CHOICE OF RADIATION MODALITY [J].
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1982, 21 (06) :469-479
[2]  
BROWN JM, 1992, INT J RADIAT ONCOL, V24, P279, DOI 10.1016/0360-3016(92)90682-8
[3]  
BUFFA F, 1999, MED PHYS, V26, P1120
[4]  
di Sopra FM, 1999, MED PHYS, V26, P2000, DOI 10.1118/1.598705
[5]  
Dudewicz E., 1988, MODERN MATH STAT
[6]   Predictive assays of radiation response in patients with head and neck squamous cell carcinoma: A review of the Institute Gustave Roussy experience [J].
Eschwege, F ;
Bourhis, J ;
Girinski, T ;
Lartigau, E ;
Guichard, M ;
Deble, D ;
Kepta, L ;
Wilson, GD ;
Luboinski, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :849-853
[7]   Predicting the radiation control probability of heterogeneous tumour ensembles: data analysis and parameter estimation using a closed-form expression [J].
Fenwick, JD .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2159-2178
[8]  
*ICRU, 1984, 137 ICRU
[9]   The effect of dose calculation uncertainty on the evaluation of radiotherapy plans [J].
Keall, PJ ;
Siebers, JV ;
Jeraj, R ;
Mohan, R .
MEDICAL PHYSICS, 2000, 27 (03) :478-484
[10]  
MA CM, 1996, POIRS0509B NRCC