Predictive utility of pulse pressure and other blood pressure measures for cardiovascular outcomes

被引:87
作者
Mosley, William J., II
Greenland, Philip
Garside, Daniel B.
Lloyd-Jones, Donald M.
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Prevent Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Bluhm Cardiovasc Inst, Chicago, IL 60611 USA
[3] Northwestern Univ, Feinberg Sch Med, Dept Med, Chicago, IL 60611 USA
关键词
hypertension; pulse pressure; stroke; coronary heart disease; heart failure; prediction;
D O I
10.1161/HYPERTENSIONAHA.106.083592
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Data are sparse regarding the actual predictive utility of pulse pressure and other blood pressure measures for cardiovascular events. We included all of the participants from the Chicago Heart Association Detection Project in Industry who were free of cardiovascular disease and not receiving antihypertensive treatment at baseline (1967-1973). Baseline blood pressure measures were assessed for predictive utility for fatal and nonfatal events over 33 years. Among 36 +/- 314 participants (mean age: 39 +/- 13 years; 43.4% women), there were 11 452 deaths: 745 were attributed to stroke, 2812 to coronary disease, and 599 to heart failure. Of the 16 393 participants who attained Medicare eligibility, 3050, 1367, and 2207 had >= 1 hospitalization for stroke, myocardial infarction, or heart failure, respectively. In univariate analyses, hazards ratios for stroke death per SD of pulse, systolic, and diastolic pressure, respectively, were 1.49, 1.75, and 1.71. Likelihood ratio chi(2) (134.3, 302.0, and 232.6, respectively), Bayes information criteria values (15 142, 14 974, and 15 044, respectively), and areas under receiver-operating characteristic curves (0.59, 0.64, and 0.63, respectively) all indicated better predictive utility for systolic and diastolic compared with pulse pressure. Results for coronary or heart failure death and stroke, myocardial infarction, or heart failure hospitalization were similar. Pulse pressure had weaker predictive utility at all ages but particularly for those < 50 years. In this large cohort study, pulse pressure had predictive utility for cardiovascular events that was inferior to systolic or diastolic pressure. These findings support the approach of current guidelines in the use of systolic and diastolic blood pressure to assess risk and the need for treatment.
引用
收藏
页码:1256 / 1264
页数:9
相关论文
共 34 条
[1]  
[Anonymous], 1991, JAMA, V265, P3255
[2]   Pulse pressure and cardiovascular mortality in normotensive and hypertensive subjects [J].
Benetos, A ;
Rudnichi, A ;
Safar, M ;
Guize, L .
HYPERTENSION, 1998, 32 (03) :560-564
[3]  
CHAO CU, 1999, JAMA-J AM MED ASSOC, V281, P634
[4]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[5]  
COX DR, 1972, J R STAT SOC B, V34, P187
[6]  
*DEP HLTH HUM SERV, 1980, INT CLASS DIS 9 REV
[7]   Isolated systolic hypertension - Prognostic information provided by pulse pressure [J].
Domanski, MJ ;
Davis, BR ;
Pfeffer, MA ;
Kastantin, M ;
Mitchell, GF .
HYPERTENSION, 1999, 34 (03) :375-380
[8]   Is pulse pressure useful in predicting risk for coronary heart disease? The Framingham Heart Study [J].
Franklin, SS ;
Khan, SA ;
Wong, ND ;
Larson, MG ;
Levy, D .
CIRCULATION, 1999, 100 (04) :354-360
[9]  
Franklin SS, 2002, HYPERTENSION, V39, pE12
[10]  
Franklin SS, 1997, CIRCULATION, V96, P308