Circle of Willis: Morphologic variation on three-dimensional time-of-flight MR angiograms

被引:291
作者
Krabbe-Hartkamp, MJ
van der Grond, J
de Leeuw, FE
de Groot, JC
Algra, A
Hillen, B
Breteler, MMB
Mali, WPTM
机构
[1] Univ Utrecht Hosp, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Erasmus Univ, Sch Med, Dept Epidemiol & Biostat, NL-3000 DR Rotterdam, Netherlands
[3] Univ Utrecht, Sch Med, Julius Ctr Patient Oriented Res, Utrecht, Netherlands
[4] Fac Med, Dept Funct Anat, Utrecht, Netherlands
关键词
brain; blood flow; cerebral blood vessels; anatomy; MR; magnetic resonance (MR); time of flight; vascular studies;
D O I
10.1148/radiology.207.1.9530305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To establish normal reference values for the presence. of the anatomic variants of the circle of Willis and average diameters for its component vessels by using three-dimensional time-of-fight magnetic resonance(MR) angiography and to determine whether age- or sex-related differences exist in the circle's anatomy. MATERIALS AND METHODS: One hundred fifty volunteers were grouped according to age: those aged 20-25 years (n = 50) and those aged 60-88 years (n - 100). All subjects underwent three-dimensional time-of-flight MR angiography of the arterial circle at 1.5 T. The anatomic variants of the anterior and posterior parts of the circle were determined separately, the completeness of the entire circle was assessed, and the diameters of all component vessels were measured. RESULTS: On MR angiograms, 111 (74%) subjects demonstrated a complete anterior part of the circle, 78 (52%) demonstrated a complete posterior part of the circle, and 63 (42%) demonstrated an entirely complete circle of Willis (complete anterior and posterior parts of the circle combined). The presence of an entirely complete circle of Willis was slightly higher in younger persons and in women. Most vessel diameters were smaller in women, except for the diameter of the posterior communicating artery. Statistically significant differences were found in vessel diameters between the younger and the older age groups. CONCLUSION: The authors determined normal reference values for morphologic variants and diameter measurements of the circle of Willis specific to three-dimensional time-of-flight MR angiography.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 37 条
[1]   CIRCLE OF WILLIS IN CEREBRAL VASCULAR DISORDERS - ANATOMICAL STRUCTURE [J].
ALPER, BJ ;
BERRY, RG .
ARCHIVES OF NEUROLOGY, 1963, 8 (04) :398-&
[2]   ANATOMICAL STUDIES OF THE CIRCLE OF WILLIS IN NORMAL BRAIN [J].
ALPERS, BJ ;
BERRY, RG ;
PADDISON, RM .
ARCHIVES OF NEUROLOGY AND PSYCHIATRY, 1959, 81 (04) :409-418
[3]   CIRCLE OF WILLIS - INCIDENCE OF DEVELOPMENTAL ABNORMALITIES IN NORMAL AND INFARCTED BRAINS [J].
BATTACHARJI, SK ;
HUTCHINSON, EC ;
MCCALL, AJ .
BRAIN, 1967, 90 :747-+
[4]  
BRUNEREAU L, 1995, J RADIOL, V76, P573
[5]  
BUSWELL HR, 1993, RADIOLOGY, V189, P397
[6]   CORRELATION OF CINE MR VELOCITY-MEASUREMENTS IN THE INTERNAL CAROTID-ARTERY WITH COLLATERAL FLOW IN THE CIRCLE OF WILLIS - PRELIMINARY-STUDY [J].
DAVIS, WL ;
TURSKI, PA ;
GORBATENKO, KG ;
WEBER, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04) :603-609
[7]   REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL ;
CAO, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :733-741
[8]   MAGNETIC-RESONANCE-IMAGING OF FLOW DYNAMICS IN THE CIRCLE OF WILLIS [J].
EDELMAN, RR ;
MATTLE, HP ;
OREILLY, GV ;
WENTZ, KU ;
LIU, C ;
ZHAO, B .
STROKE, 1990, 21 (01) :56-65
[9]  
ENZMANN DR, 1994, AM J NEURORADIOL, V15, P123
[10]  
FURST G, 1993, J COMPUT ASSIST TOMO, V17, P178, DOI 10.1097/00004728-199303000-00004