Time-frequency analysis of the first heart sound. Part 1: Simulation and analysis

被引:24
作者
Chen, D
Durand, LG
Lee, HC
机构
[1] Inst Rech Clin Montreal, Lab Genie Biomed, Montreal, PQ H2W 1R7, Canada
[2] McGill Univ, Dept Elect Engn, Montreal, PQ H3A 2A7, Canada
基金
英国医学研究理事会;
关键词
first heart sound; simulation; spectrogram; time-frequency representation;
D O I
10.1007/BF02534081
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The authors propose a simulated first heart sound (S1) signal that can be used as a reference signal to evaluate the accuracy of time-frequency representation techniques for studying multicomponent signals. The composition of this simulated SI is based on the hypothesis that an S1 recorded on the thorax over the apical area of the heart is composed of constant frequency vibrations from the mitral valve and a frequency modulated vibration from the myocardium. Essentially, the simulated S1 consists of a valvular component and a myocardial component. The valvular component is modelled as two exponentially decaying sinusoids of 50 Hz and 150 Hz and the myocardial component is modelled by a frequency modulated wave between 20 Hz and 100 Hz. The study shows that the simulated S1 has temporal and spectral characteristics similar to SI recorded in humans and dogs. It also shows that the spectrogram cannot resolve the three components of the simulated SI. It is concluded that it is necessary to search for a better time-frequency representation technique for studying the time-frequency distribution of multicomponent signals such as the simulated SI.
引用
收藏
页码:306 / 310
页数:5
相关论文
共 27 条
[1]   ACOUSTIC-SIGNALS FROM SKELETAL-MUSCLE [J].
BARRY, DT .
NEWS IN PHYSIOLOGICAL SCIENCES, 1990, 5 :17-21
[2]  
BARRY DT, 1991, ARCH PHYS MED REHAB, V72, P573
[3]   MUSCLE SOUNDS ARE EMITTED AT THE RESONANT FREQUENCIES OF SKELETAL-MUSCLE [J].
BARRY, DT ;
COLE, NM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (05) :525-531
[4]  
BEDI R, 1994, P 16 ANN INT C IEEE, V2, P1284
[5]  
CHEN D, 1997, MED BIOL ENG COMPUT, V35
[6]  
CHEN D, 1997, MED BIOL ENB COMPUT, V35
[7]   SPECTRAL-ANALYSIS OF CLOSING SOUNDS PRODUCED BY IONESCU-SHILEY BIOPROSTHETIC AORTIC HEART-VALVES .2. COMPUTER-SIMULATION OF AORTIC CLOSING SOUNDS AND ESTIMATION OF THEIR TRUNCATION LEVEL AND SIGNAL-TO-NOISE RATIO [J].
CLOUTIER, G ;
GRENIER, MC ;
GUARDO, R ;
DURAND, LG .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (05) :492-496
[8]   TIME FREQUENCY-DISTRIBUTIONS - A REVIEW [J].
COHEN, L .
PROCEEDINGS OF THE IEEE, 1989, 77 (07) :941-981
[9]   Digital signal processing of the phonocardiogram: Review of the most recent advancements [J].
Durand, LG ;
Pibarot, P .
CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1995, 23 (3-4) :163-219
[10]   MODELING OF THE TRANSFER-FUNCTION OF THE HEART THORAX ACOUSTIC SYSTEM IN DOGS [J].
DURAND, LG ;
GENEST, J ;
GUARDO, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (08) :592-601