Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs

被引:68
作者
Greer, Rebecca J. [1 ]
Cohn, Leah A. [1 ]
Dodam, John R. [1 ]
Wagner-Mann, Colette C. [1 ]
Mann, F. A. [1 ]
机构
[1] Univ Missouri, Coll Vet Med, Dept Vet Med & Surg, Columbia, MO 65211 USA
来源
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION | 2007年 / 230卷 / 12期
关键词
D O I
10.2460/javma.230.12.1841
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective - To assess the reliability and accuracy of a predictive rectal thermometer, an infrared auricular thermometer designed for veterinary use, and a subcutaneous temperature-sensing microchip for measurement of core body temperature over various temperature conditions in dogs. Design - Prospective study. Animals - 8 purpose-bred dogs. Procedures - A minimum of 7 days prior to study commencement, a subcutaneous temperature-sensing microchip was implanted in 1 of 3 locations (interscapular, lateral aspect of shoulder, or sacral region) in each dog. For comparison with temperatures measured via rectal thermometer, infrared auricular thermometer, and microchip, core body temperature was measured via a thermistor-tipped pulmonary artery (TTPA) catheter. Hypothermia was induced during anesthesia at the time of TTPA catheter placement:, on 3 occasions after placement of the catheter, hyperthermia was induced via administration of a low dose of endotoxin. Near-simultaneous duplicate temperature measurements were recorded from the TTPA catheter, the rectal thermometer, auricular thermometer, and subcutaneous microchips during hypothermia, euthermia, and hyperthermia. Reliability (variability) of temperature measurement for each device and agreement between each device measurement and core body temperature were assessed. Results-Variability between duplicate near-simultaneous temperature measurements was greatest for the auricular thermometer and least for the TTPA catheter. Measurements obtained by use of the rectal thermometer were in closest agreement with core body temperature;, for all other devices, temperature readings typically underestimated core body temperature. Conclusions and Clinical Relevance - Among the 3 methods of temperature measurement, rectal thermometry provided the most accurate estimation of core body temperature in dogs.
引用
收藏
页码:1841 / 1848
页数:8
相关论文
共 25 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Chen PH, 2006, J AM ASSOC LAB ANIM, V45, P57
[3]   In a systematic review, infrared ear thermometry for fever diagnosis in children finds poor sensitivity [J].
Dodd, SR ;
Lancaster, GA ;
Craig, JV ;
Smyth, RL ;
Williamson, PR .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (04) :354-357
[4]   Monitoring urinary bladder temperature in the intensive care unit: State of the science [J].
Fallis, WM .
AMERICAN JOURNAL OF CRITICAL CARE, 2002, 11 (01) :38-47
[5]   ESTIMATION OF BODY SITES TEMPERATURES FROM TYMPANIC MEASUREMENTS [J].
FRADEN, J ;
LACKEY, RP .
CLINICAL PEDIATRICS, 1991, 30 (04) :65-70
[6]   BODY-COMPOSITION AND SKIN TEMPERATURE-VARIATION [J].
FRIM, J ;
LIVINGSTONE, SD ;
REED, LD ;
NOLAN, RW ;
LIMMER, RE .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 68 (02) :540-543
[7]   Measurement of body temperature by use of auricular thermometers versus rectal thermometers in dogs with otitis externa [J].
González, AM ;
Mann, FA ;
Preziosi, DE ;
Meadows, RL ;
Wagner-Mann, CC .
JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2002, 221 (03) :378-380
[8]  
Goodwin SD, 1998, CONTEMP TOP LAB ANIM, V37, P51
[9]   When body temperature changes, does rectal temperature lag? [J].
Greenes, DS ;
Fleisher, GR .
JOURNAL OF PEDIATRICS, 2004, 144 (06) :824-826
[10]   Monitoring body-core temperature from the trachea: Comparison between pulmonary artery, tympanic, esophageal, and rectal temperatures [J].
Hayes, JK ;
Collette, DJ ;
Peters, JL ;
Smith, KW .
JOURNAL OF CLINICAL MONITORING, 1996, 12 (03) :261-269