Pilot study for the Standardization of insulin immunoassays with isotope dilution-liquid chromatography/tandem mass spectrometry

被引:45
作者
Rodriguez-Cabaleiro, Diego
Van Uytfanghe, Katleen
Stove, Veronique
Fiers, Tom
Thienpont, Linda M.
机构
[1] Univ Ghent, Fac Pharmaceut Sci, Analyt Chem Lab, B-9000 Ghent, Belgium
[2] Univ Ghent, Lab Hormonol, B-9000 Ghent, Belgium
[3] Univ Ghent, Dept Endocrinol, B-9000 Ghent, Belgium
关键词
D O I
10.1373/clinchem.2007.088393
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: An international working group convened by the American Diabetes Association (ADA) called for a reference measurement procedure for use in a trueness-based standardization project of insulin immunoassays. In view of this demand, we conducted a pilot study to investigate the feasibility of such a standardization project with our isotope dilution-liquid chromatography/tandem mass spectrometry (ID-LC/tandem MS) procedure. Methods: We evaluated the precision, accuracy, and limit of quantification (LoQ) of the ID-LC/tandem MS procedure by use of insulin-free serum supplemented with insulin to give 3 pools with concentrations of 0.0796, 0.769, and 5.56 mu g/L. We conducted a pilot method comparison study with 4 immunoassays and 80 samples from fasting and glucose-stimulated patients. Results: The within-run and total imprecision (CV) ranged from 3.2% to 6.3% and from 4.9% to 12.1% (listing sequence from the high to the low pool). The recovery from supplemented insulin-free sera ranged from 101.8% to 104.1%, and the LoQ was 0.07 mu g/L (12 pmol/L). Weighted Deming regression and correlation analysis of the method-comparison data showed considerable between-assay variation for the immunoassays but, with the exception of one assay, excellent correlation with ID-LC/tandem MS. Recalibration of the immunoassay results considerably reduced the between-assay variation. Moreover, after recalibration, 3 of the 4 assays fulfilled the total error specification of 32% proposed by the ADA Workgroup. Conclusions: Recalibration of insulin assays by regression equations established from method comparison with ID-LC/tandem MS can result in successful standardization and fulfillment of the total error criterion proposed by the ADA Workgroup. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:1462 / 1469
页数:8
相关论文
共 7 条
[1]  
Deberg M, 1998, CLIN CHEM, V44, P1504
[2]   Comparison of 11 human insulin assays: Implications for clinical investigation and research [J].
Manley, Susan E. ;
Stratton, Irene M. ;
Clark, Penelope M. ;
Luzio, Stephen D. .
CLINICAL CHEMISTRY, 2007, 53 (05) :922-932
[3]   Standardization of insulin immunoassays: Report of the American Diabetes Association Workgroup [J].
Marcovina, Santica ;
Bowsher, Ronald R. ;
Miller, W. Greg ;
Staten, Myrlene ;
Myers, Gary ;
Caudill, Samuel P. ;
Campbell, Scott E. ;
Steffes, Michael W. .
CLINICAL CHEMISTRY, 2007, 53 (04) :711-716
[4]   Report of the American Diabetes Association's task force on standardization of the insulin assay [J].
Robbins, DC ;
Andersen, L ;
Bowsher, R ;
Chance, R ;
Dinesen, B ;
Frank, B ;
Gingerich, R ;
Goldstein, D ;
Widemeyer, HM ;
Haffner, S ;
Hales, CN ;
Jarett, L ;
Polonsky, K ;
Porte, D ;
Skyler, J ;
Webb, G ;
Gallagher, K .
DIABETES, 1996, 45 (02) :242-256
[5]  
Thienpont LM, 1996, J MASS SPECTROM, V31, P1119, DOI 10.1002/(SICI)1096-9888(199610)31:10<1119::AID-JMS404>3.0.CO
[6]  
2-X
[7]   New liquid chromatography/electrospray ionisation tandem mass spectrometry measurement procedure for quantitative analysis of human insulin in serum [J].
Van Uyfanghe, Katleen ;
Rodriguez-Cabaleiro, Diego ;
Stockl, Dietmar ;
Thienpont, Linda M. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (05) :819-821