Model of the negative DC corona plasma: Comparison to the positive DC corona plasma

被引:191
作者
Chen, JH [1 ]
Davidson, JH [1 ]
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
关键词
corona discharge; corona plasma; plasma-enhanced chemical reactions; photoemission; Townsend second ionization coefficient; electrostatic precipitator;
D O I
10.1023/A:1022468803203
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A numerical model of the negative DC corona plasma along a thin wire in dry air is presented. The electron number density and electric field are determined from solution of the one-dimensional coupled continuity equations of charge carriers and Maxwell's equation. The electron kinetic energy distribution is determined from the spatially homogeneous Boltzmann equation. A parametric study is conducted to examine the effects of linear current density (0.1-100 muA per cm of wire length), wire radius (10-1000 mum), and air temperature (293-800 K) on the distribution of electrons and the Townsend second ionization coefficient. The results are compared to those previously determined for the positive corona discharge. In the negative corona, energetic electrons are present beyond the ionization boundary and the number of electrons is an order of magnitude greater than in the positive corona. The number of electrons increases with increasing gas temperature. The electron energy distribution does not depend on discharge polarity.
引用
收藏
页码:83 / 102
页数:20
相关论文
共 53 条
[1]   The influence of electrode geometry and gas flow on corona-to-glow and glow-to-spark threshold currents in air [J].
Akishev, Y ;
Goossens, O ;
Callebaut, T ;
Leys, C ;
Napartovich, A ;
Trushkin, N .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (18) :2875-2882
[2]  
AKISHEV Y, 2000, P INT S HIGH PRESS L, V2, P481
[3]  
ALEKSANDROV GN, 1956, SOV PHYS-TECH PHYS, V1, P1714
[4]  
[Anonymous], NONTHERMAL PLASMA EX
[5]   OZONE GENERATION IN AN ELECTROSTATIC PRECIPITATOR WITH A HEATED CORONA WIRE [J].
AWAD, MB ;
CASTLE, GSP .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1975, 25 (04) :369-374
[6]  
BOELTER K, 1996, THESIS U MINNESOTA M
[7]   Ozone generation by indoor, electrostatic air cleaners [J].
Boelter, KJ ;
Davidson, JH .
AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (06) :689-708
[8]   Ozone production in the positive DC corona discharge: Model and comparison to experiments [J].
Chen, JH ;
Davidson, JH .
PLASMA CHEMISTRY AND PLASMA PROCESSING, 2002, 22 (04) :495-522
[9]   Electron density and energy distributions in the positive DC corona: Interpretation for corona-enhanced chemical reactions [J].
Chen, JH ;
Davidson, JH .
PLASMA CHEMISTRY AND PLASMA PROCESSING, 2002, 22 (02) :199-224
[10]  
Cobine J. D., 1958, GASEOUS CONDUCTORS T