Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model

被引:43
作者
Bozkurt, A
Chao, TC
Xu, XG
机构
[1] Rensselaer Polytech Inst, Dept Environm & Energy Engn, Nucl Engn Program, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Dept Environm & Energy Engn, Engn Phys Program, Troy, NY 12180 USA
关键词
D O I
10.1088/0031-9155/45/10/321
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients have been calculated for neutrons below 20 MeV using a whole-body anatomical model, VIP-Man, developed from the high-resolution transverse colour photographic images of the National Library of Medicine's Visible Human Project(R). Organ dose calculations were performed using the Monte Carlo code MCNP for 20 monoenergetic neutron beams between 1 x 10(-9) MeV and 20 MeV under six different irradiation geometries: anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic. The absorbed dose for 24 major organs and effective dose results based on the realistic VIP-Man are presented and compared with those based on the simplified MIRD-based phantoms reported in the literature. Effective doses from VIP-Man are not significantly different from earlier results for neutrons in the energy range studied. There are, however, remarkable deviations in organ doses due to the anatomical differences between the image-based and the earlier mathematical models.
引用
收藏
页码:3059 / 3079
页数:21
相关论文
共 26 条
[1]   ABSORBED DOSE AND DOSE EQUIVALENT FROM NEUTRONS IN ENERGY RANGE 60 TO 3000 MEV AND PROTONS IN ENERGY RANGE 400 TO 3000 MEV [J].
ALSMILLER, RG ;
ARMSTRONG, TW ;
COLEMAN, WA .
NUCLEAR SCIENCE AND ENGINEERING, 1970, 42 (03) :367-+
[2]  
[Anonymous], 1989, TISS SUBST RAD DOS M
[3]  
BOZKURT A, 2000, UNPUB HLTH PHYS
[4]  
Briesmeister JF., 1997, ALAMOS NATL LAB REPO, pLA
[5]  
CHAO TC, 2000, UNPUB HLTH PHYS
[6]   CALCULATION OF FAST-NEUTRON DEPTH-DOSE IN THE ICRU STANDARD TISSUE PHANTOM AND THE DERIVATION OF NEUTRON FLUENCE-TO-DOSE-INDEX CONVERSION FACTORS [J].
CHEN, SY ;
CHILTON, AB .
RADIATION RESEARCH, 1979, 78 (03) :335-370
[7]  
Cristy M, 1987, ORNL/TM-8381 V1-V7
[8]  
HOLLANGEL RA, 1994, RADIAT PROT DOSIM, V54, P227
[9]   EFFECTIVE DOSE EQUIVALENT AND ORGAN DOSES FOR NEUTRONS FROM THERMAL TO 14 MEV [J].
HOLLNAGEL, RA .
RADIATION PROTECTION DOSIMETRY, 1990, 30 (03) :149-159
[10]  
HOLLNAGEL RA, 1992, RADIAT PROT DOSIM, V44, P155