0.2-Hz repetitive transcranial magnetic stimulation has no add-on effects as compared to a realistic sham stimulation in Parkinson's disease

被引:110
作者
Okabe, S [1 ]
Ugawa, Y [1 ]
Kanazawa, I [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Neurol, Div Neurosci,Bunkyo Ku, Tokyo 1138655, Japan
关键词
Parkinson's disease; repetitive transcranial magnetic stimulation (rTMS); treatment; sham stimulation; placebo effect;
D O I
10.1002/mds.10370
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To study the efficacy of 0.2-Hz repetitive transcranial magnetic stimulation (rTMS) on Parkinson's disease (PD), 85 patients with PD were enrolled into three groups: 1) motor cortical, 2) occipital, and 3) sham stimulation. A round coil was centered over the vertex in motor cortical stimulation, and over the inion in occipital stimulation. In one session, 100 stimuli of 0.2-Hz rTMS at an intensity of 1.1 times active motor threshold (AMT) were given. In sham stimulation, electric currents were given with electrodes fixed on the head to mimic the sensation in real stimulation. Each session was carried out once a week for the first 8 weeks. The Unified Parkinson Disease Rating Scale (UPDRS), Hamilton Rating Scale for Depression (HRSD) and subjective score (visual analogue scale) were assessed. There were no significant differences in clinical features among the three groups. Total and motor score of UPDRS were improved to the same extent by rTMS over Cz, inion, and sham stimulation. HRSD was improved by rTMS over Cz and sham stimulation in the same manner. Subjective score was not significantly improved by any methods of stimulation. 0.2-Hz rTMS at an intensity of 1.1 X AMT has only a placebo effect on PD. Our realistic sham stimulation maneuver must produce powerful placebo effects as a real stimulation. (C) 2002 Movement Disorder Society.
引用
收藏
页码:382 / 388
页数:7
相关论文
共 23 条
[1]   Repetitive transcranial magnetic stimulation to SMA worsens complex movements in Parkinson's disease [J].
Boylan, LS ;
Pullman, SL ;
Lisanby, SH ;
Spicknall, KE ;
Sackeim, HA .
CLINICAL NEUROPHYSIOLOGY, 2001, 112 (02) :259-264
[2]   Transcranial magnetic stimulation and Parkinson's disease [J].
Cantello, R ;
Tarletti, R ;
Civardi, C .
BRAIN RESEARCH REVIEWS, 2002, 38 (03) :309-327
[3]   Depression of motor cortex excitability by low-frequency transcranial magnetic stimulation [J].
Chen, R ;
Classen, J ;
Gerloff, C ;
Celnik, P ;
Wassermann, EM ;
Hallett, M ;
Cohen, LG .
NEUROLOGY, 1997, 48 (05) :1398-1403
[4]   Contralateral and ipsilateral repetitive transcranial magnetic stimulation in patients with Parkinson's disease [J].
de Groot, M ;
Hermann, W ;
Steffen, J ;
Wagner, A ;
Grahmann, F .
NERVENARZT, 2001, 72 (12) :932-938
[5]   Expectation and dopamine release:: Mechanism of the placebo effect in Parkinson's disease [J].
de la Fuente-Fernández, R ;
Ruth, TJ ;
Sossi, V ;
Schulzer, M ;
Calne, DB ;
Stoessl, AJ .
SCIENCE, 2001, 293 (5532) :1164-1166
[6]   RELIABILITY, VALIDITY, AND CLINICAL APPLICATION OF VISUAL ANALOG MOOD SCALE [J].
FOLSTEIN, MF ;
LURIA, R .
PSYCHOLOGICAL MEDICINE, 1973, 3 (04) :479-486
[7]   A controlled trial of daily left prefrontal cortex TMS for treating depression [J].
George, MS ;
Nahas, Z ;
Molloy, M ;
Speer, AM ;
Oliver, NC ;
Li, XB ;
Arana, GW ;
Risch, SC ;
Ballenger, JC .
BIOLOGICAL PSYCHIATRY, 2000, 48 (10) :962-970
[8]   Simultaneous repetitive transcranial magnetic stimulation does not speed fine movement in PD [J].
Ghabra, MB ;
Hallett, M ;
Wassermann, EM .
NEUROLOGY, 1999, 52 (04) :768-770
[9]   Objective changes in motor function during placebo treatment in PD [J].
Goetz, CG ;
Leurgans, S ;
Raman, R ;
Stebbins, GT .
NEUROLOGY, 2000, 54 (03) :710-714
[10]   ACCURACY OF CLINICAL-DIAGNOSIS OF IDIOPATHIC PARKINSONS-DISEASE - A CLINICOPATHOLOGICAL STUDY OF 100 CASES [J].
HUGHES, AJ ;
DANIEL, SE ;
KILFORD, L ;
LEES, AJ .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1992, 55 (03) :181-184