Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology

被引:205
作者
Siewerdsen, JH
Antonuk, LE
El-Mohri, Y
Yorkston, J
Huang, W
Cunningham, IA
机构
[1] Univ Michigan, Med Ctr, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, Dept Physiol, London, ON N6A 5K8, Canada
[4] London Hlth Sci Ctr Victoria, Dept Diagnost Radiol, London, ON N6A 5K8, Canada
关键词
digital x-ray imaging; flat-panel imager; amorphous silicon; noise power spectrum; detective quantum efficiency; cascaded systems analysis;
D O I
10.1118/1.598243
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 mu m pitch array of a-Si:H thin-film transistors and photodiodes, the Fl?I was developed as a prototype for examination of the potential of flat-panel technology in diagnostic x-ray imaging. The signal size per unit exposure (x-ray sensitivity) was measured for the FPI incorporating five commercially available Gd2O2S:Tb converting screens at energies 70-120 kVp. One-dimensional and two-dimensional NPS and DQE were measured for the FPI incorporating three such converters and as a function of the incident exposure. The measurements support the hypothesis that FPIs have significant potential for application in diagnostic radiology. A cascaded systems model that has shown good agreement with measured individual pixel signal and noise properties is employed to describe the performance of various FPI designs and configurations under a variety of diagnostic imaging conditions. Theoretical x-ray sensitivity; NPS, and DQE are compared to empirical results, and good agreement is observed in each case. The model is used to describe the potential performance of FPIs incorporating a recently developed, enhanced array that is commercially available and has been proposed for testing and application in diagnostic radiography and fluoroscopy. Under conditions corresponding to chest radiography, the analysis suggests that such systems can potentially meet or even exceed the DQE performance of existing technology, such as screen-film and storage phosphor systems; however, under conditions corresponding to general fluoroscopy, the typical exposure per frame is such that the DQE is limited by the total system gain and additive electronic noise. The cascaded systems analysis provides a valuable means of identifying the limiting stages of the imaging system, a tool for system optimization, and a guide for developing strategies of FPI design for various imaging applications. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:614 / 628
页数:15
相关论文
共 44 条
  • [1] Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager
    Antonuk, LE
    Yorkston, J
    Huang, WD
    Sandler, H
    Siewerdsen, JH
    ElMohri, Y
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03): : 661 - 672
  • [2] Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
    Antonuk, LE
    ElMohri, Y
    Siewerdsen, JH
    Yorkston, J
    Huang, W
    Scarpine, VE
    Street, RA
    [J]. MEDICAL PHYSICS, 1997, 24 (01) : 51 - 70
  • [3] DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS
    ANTONUK, LE
    BOUDRY, J
    HUANG, WD
    MCSHAN, DL
    MORTON, EJ
    YORKSTON, J
    LONGO, MJ
    STREET, RA
    [J]. MEDICAL PHYSICS, 1992, 19 (06) : 1455 - 1466
  • [4] THIN-FILM, FLAT-PANEL, COMPOSITE IMAGERS FOR PROJECTION AND TOMOGRAPHIC IMAGING
    ANTONUK, LE
    BOUDRY, J
    HUANG, WD
    LAM, KL
    MORTON, EJ
    TENHAKEN, RK
    YORKSTON, J
    CLINTHORNE, NH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) : 482 - 490
  • [5] ANTONUK LE, 1994, IEEE T NUCL SCI, V14, P1500
  • [6] Bendat JS., 2011, RANDOM DATA ANAL MEA
  • [7] BIRCH R, 1979, HOSP PHYS ASS SCI RE, V30, P20
  • [8] A SURVEY OF FLUOROSCOPIC EXPOSURE RATES - AAPM TASK GROUP NO 11 REPORT
    BOONE, JM
    PFEIFFER, DE
    STRAUSS, KJ
    ROSSI, RP
    LIN, PJP
    SHEPARD, JS
    CONWAY, BJ
    [J]. MEDICAL PHYSICS, 1993, 20 (03) : 789 - 794
  • [9] RADIATION-DAMAGE OF AMORPHOUS-SILICON PHOTODIODE SENSORS
    BOUDRY, JM
    ANTONUK, LE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 703 - 707
  • [10] Radiation damage of amorphous silicon, thin-film, field-effect transistors
    Boudry, JM
    Antonuk, LE
    [J]. MEDICAL PHYSICS, 1996, 23 (05) : 743 - 754