Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I - Correlating internal lung motion with skin fiducial motion

被引:166
作者
Koch, N
Liu, HH
Starkschall, G
Jacobson, M
Forster, K
Liao, ZX
Komaki, R
Stevens, CW
机构
[1] Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Div Diagnost Imaging, Houston, TX USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 60卷 / 05期
关键词
lung motion; motion tracking; MRI; respiratory gating;
D O I
10.1016/j.ijrobp.2004.05.055
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: To measure the internal lung motion due to respiration using magnetic resonance images (MRIs); to evaluate the correlation between lung motion and skin surface motion and the reliability of tracking lung motion with external fiducials. Methods and Materials: An MRI protocol using fast gradient-echo sequences was developed to acquire dynamic cine images of the thoracoabdominal region along the axial, sagittal, and coronal planes. The subjects (3 healthy volunteers and 4 lung cancer patients) were instructed to perform normal or altered breathing during MRI. Lung vessels identified on MRI were used as anatomic landmarks for internal lung structures. From sagittal cine MRI scans, the positions of the lung vessels and skin surface were tracked and their movements measured. Correlation between the movements of the external markers and internal structures was then calculated and analyzed. Results: Lung vessel motion in the superior-inferior (SI) direction correlated best with mid-upper abdominal skin surface movement (correlation coefficient, 0.89 +/- 0.09 and 0.87 +/- 0.23 for volunteers and patients, respectively). The anterior-posterior (AP) vessel motion generally correlated poorly with the skin surface movement, with marker placement on the upper chest yielding the strongest results (correlation coefficient, 0.72 +/- 0.23 and 0.44 +/- 0.27 for volunteers and patients, respectively). The strength of the correlation depended on the locations of the tracked vessels, locations of the skin surface, and subjects' breathing patterns. The best correlation was seen between the motion of an abdominal fiducial and SI lung motion. Significant intersubject variability was also observed. Conclusion: Movement of an external fiducial may not correlate fully with, or predict, internal lung motion. Effective monitoring of respiration may have to rely on a combination of multiple fiducials and other physiologic parameters, such as lung volume and/or air flow. (C) 2004 Elsevier Inc.
引用
收藏
页码:1459 / 1472
页数:14
相关论文
共 14 条
[1]
Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients [J].
Chen, QS ;
Weinhous, MS ;
Deibel, FC ;
Ciezki, JP ;
Macklis, RM .
MEDICAL PHYSICS, 2001, 28 (09) :1850-1856
[2]
Conformal radiotherapy (CRT) planning for lung cancer: Analysis of intrathoracic organ motion during extreme phases of breathing [J].
Giraud, P ;
De Rycke, Y ;
Dubray, B ;
Helfre, S ;
Voican, D ;
Guo, L ;
Rosenwald, JC ;
Keraudy, K ;
Housset, M ;
Touboul, E ;
Cosset, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :1081-1092
[3]
*INT COMM RAD UN M, 1999, 62 ICRU INT COMM RAD
[4]
*INT COMM RAD UN M, 1999, 50 ICRU INT COMM RAD
[5]
Koch N, 2003, J Appl Clin Med Phys, V4, P352, DOI 10.1120/1.1617211
[6]
Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center [J].
Kubo, HD ;
Len, PM ;
Minohara, S ;
Mostafavi, H .
MEDICAL PHYSICS, 2000, 27 (02) :346-353
[7]
Mageras G S, 2001, J Appl Clin Med Phys, V2, P191, DOI 10.1120/1.1409235
[8]
Issues in respiratory motion compensation during external-beam radiotherapy [J].
Ozhasoglu, C ;
Murphy, MJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05) :1389-1399
[9]
The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer [J].
Rosenzweig, KE ;
Hanley, J ;
Mah, D ;
Mageras, G ;
Hunt, M ;
Toner, S ;
Burman, C ;
Ling, CC ;
Mychalczak, B ;
Fuks, Z ;
Leibel, SA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01) :81-87
[10]
ANALYSIS OF MOVEMENT OF INTRATHORACIC NEOPLASMS USING ULTRAFAST COMPUTERIZED-TOMOGRAPHY [J].
ROSS, CS ;
HUSSEY, DH ;
PENNINGTON, EC ;
STANFORD, W ;
DOORNBOS, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03) :671-677