Microvolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy - A solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II conundrum

被引:232
作者
Bloomfield, DM
Steinman, RC
Namerow, PB
Parides, M
Davidenko, J
Kaufman, ES
Shinn, T
Curtis, A
Fontaine, J
Holmes, D
Russo, A
Tang, C
Bigger, JT
机构
[1] Columbia Univ, Dept Med, New York, NY USA
[2] Case Western Reserve Univ, MetroHlth, Cleveland, OH 44106 USA
[3] New York Heart Ctr, Syracuse, NY USA
[4] Michigan Heart PC, Ypsilanti, MI USA
[5] Univ Florida, Gainesville, FL USA
[6] Drexel Univ, Coll Med, Philadelphia, PA 19104 USA
[7] NYU, New York, NY USA
[8] Univ Penn, Philadelphia, PA 19104 USA
[9] Minneapolis Heart Inst Fdn, Minneapolis, MN USA
关键词
heart failure; coronary disease; death; sudden; heart arrest; defibrillation;
D O I
10.1161/01.CIR.0000143160.14610.53
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - In 2003, the Centers for Medicaid and Medicare Services recommended QRS duration as a means to identify MADIT II-like patients suitable for implanted cardiac defibrillator (ICD) therapy. We compared the ability of microvolt T-wave alternans and QRS duration to identify groups at high and low risk of dying among heart failure patients who met MADIT II criteria for ICD prophylaxis. Methods and Results - Patients with MADIT II characteristics and sinus rhythm had a microvolt T-wave alternans exercise test and a 12-lead ECG. Our primary end point was 2-year all-cause mortality. Of 177 MADIT II - like patients, 32% had a QRS duration > 120 ms, and 68% had an abnormal ( positive or indeterminate) microvolt T-wave alternans test. During an average follow-up of 20 +/- 6 months, 20 patients died. We compared patients with an abnormal microvolt T-wave alternans test to those with a normal ( negative) test, and patients with a QRS > 120 ms with those with a QRS less than or equal to 120 ms; the hazard ratios for 2-year mortality were 4.8 ( P = 0.020) and 1.5 ( P = 0.367), respectively. The actuarial mortality rate was substantially lower among patients with a normal microvolt T-wave alternans test (3.8%; 95% confidence interval: 0, 9.0) than the mortality rate in patients with a narrow QRS (12.0%; 95% confidence interval: 5.6, 18.5). The corresponding false-negative rates are 3.5% and 10.2%, respectively. Conclusion - Among MADIT II - like patients, a microvolt T-wave alternans test is better than QRS duration at identifying a high-risk group and also better at identifying a low-risk group unlikely to benefit from ICD therapy.
引用
收藏
页码:1885 / 1889
页数:5
相关论文
共 21 条
  • [1] Expanding indications for implantable cardiac defibrillators
    Bigger, JT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) : 931 - 933
  • [2] Interpretation and classification of microvolt T wave alternans tests
    Bloomfield, DM
    Hohnloser, SH
    Cohen, RJ
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) : 502 - 512
  • [3] Electrophysiologic testing to identify patients with coronary artery disease who are at risk for sudden death
    Buxton, AE
    Lee, KL
    DiCarlo, L
    Gold, MR
    Greer, GS
    Prystowsky, EN
    O'Toole, MF
    Tang, A
    Fisher, JD
    Coromilas, J
    Talajic, M
    Hafley, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (26) : 1937 - 1945
  • [4] The clinical use of implantable cardioverter defibrillators: Where are we now? Where should we go?
    Buxton, AE
    [J]. ANNALS OF INTERNAL MEDICINE, 2003, 138 (06) : 512 - 514
  • [5] *CTR MED MED SERV, 2003, DEC MEM NAT COV DET
  • [6] A comparison of T-wave alternans, signal averaged electrocardiography and programmed ventricular stimulation for arrhythmia risk stratification
    Gold, MR
    Bloomfield, DM
    Anderson, KP
    El-Sherif, NE
    Wilber, DJ
    Groh, WJ
    Estes, NAM
    Kaufman, ES
    Greenberg, ML
    Rosenbaum, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (07) : 2247 - 2253
  • [7] ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices - Summary article - A report of the American College of Cardiology American Heart Association task force on practice guidelines - (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
    Gregoratos, G
    Abrams, J
    Epstein, AE
    Freedman, RA
    Hayes, DL
    Hlatky, MA
    Kerber, RE
    Naccarelli, GV
    Schoenfeld, MH
    Silka, MJ
    Winters, SL
    Gibbons, RJ
    Antman, EM
    Alpert, JS
    Gregoratos, G
    Hiratzka, LF
    Faxon, DP
    Jacobs, AK
    Fuster, V
    Smith, SC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (09) : 1703 - 1719
  • [8] T-wave alternans negative coronary patients with low ejection and benefit from defibrillator implantation
    Hohnloser, SH
    Ikeda, T
    Bloomfield, DM
    Dabbous, OH
    Cohen, RJ
    [J]. LANCET, 2003, 362 (9378) : 125 - 126
  • [9] T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: Prospective comparison with conventional risk markers
    Hohnloser, SH
    Klingenheben, T
    Li, YG
    Zabel, M
    Peetermans, J
    Cohen, RJ
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (12) : 1258 - 1268
  • [10] T-wave alternans as a predictor for sudden cardiac death after myocardial infarction
    Ikeda, T
    Saito, H
    Tanno, K
    Shimizu, H
    Watanabe, J
    Ohnishi, Y
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (01) : 79 - +