Enhanced pharmaceutical analysis by CE using dynamic surface coating system

被引:33
作者
Altria, KD [1 ]
机构
[1] Pharmaceut Dev Europe, GlaxoSmithKline Res & Dev, Ware SG12 0DP, Herts, England
关键词
pharmaceutical analysis; capillary electrophoresis; dynamic surface coating;
D O I
10.1016/S0731-7085(02)00728-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The poor repeatability of migration times in capillary electrophoresis (CE) within an injection sequence and between capillaries can be a difficulty when implementing CE for routine pharmaceutical analysis. The use of a dynamic surface coating has been shown to improve the routine performance of CE. The surface coating generates an appreciable electro-osmotic flow at low pH, which reduces analysis times for basic drugs compared to the low pH buffers typically used in CE. The repeatability of migration times and repeatability of migration times between capillaries was improved. Peak tailing for basic drugs was also reduced which improved peak shapes and peak area integration precision. It is concluded that the dynamic coating system is a positive advance in the routine implementation of CE into pharmaceutical analysis. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 15 条
  • [1] ESSENTIAL PEAK AREA NORMALIZATION FOR QUANTITATIVE IMPURITY CONTENT DETERMINATION BY CAPILLARY ELECTROPHORESIS
    ALTRIA, KD
    [J]. CHROMATOGRAPHIA, 1993, 35 (3-4) : 177 - 182
  • [2] VALIDATED CAPILLARY ELECTROPHORESIS METHOD FOR THE ASSAY OF A RANGE OF BASIC DRUGS
    ALTRIA, KD
    FRAKE, P
    GILL, I
    HADGETT, T
    KELLY, MA
    RUDD, DR
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (08) : 951 - 957
  • [3] ALTRIA KD, 1997, LC GC EUR, V10, P157
  • [4] Determination of trace enantiomeric impurities in chiral compounds by capillary electrophoresis with uncoated, cationic, anionic and neutral surface modified capillaries
    Assi, KH
    Abushoffa, AM
    Altria, KD
    Clark, BJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) : 83 - 90
  • [5] Belder D, 2001, ELECTROPHORESIS, V22, P3813, DOI 10.1002/1522-2683(200109)22:17<3813::AID-ELPS3813>3.0.CO
  • [6] 2-D
  • [7] Dynamically coated capillaries improve the identification power of capillary zone electrophoresis for basic drugs in toxicological analysis
    Boone, CM
    Jonkers, EZ
    Franke, JP
    de Zeeuw, RA
    Ensing, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) : 203 - 210
  • [8] CLOHS L, 2002, LC GC EUROPE MAY, P288
  • [9] Janssens J., 1997, U.S. Patent, Patent No. [5,611,903, 5611903]
  • [10] Kuldvee R, 2001, ELECTROPHORESIS, V22, P1345, DOI 10.1002/1522-2683(200105)22:7<1345::AID-ELPS1345>3.0.CO