Transcranial electrical motor-evoked potential monitoring during surgery for spinal deformity -: A study of 145 patients

被引:215
作者
Langeloo, DD [1 ]
Lelivelt, A
Journée, HL
Slappendel, R
de Kleuver, M
机构
[1] Sint Maartensklin, Dept Orthopaed, Hengstdal 3, NL-6522 JV Nijmegen, Netherlands
[2] Sint Maartensklin, Dept Orthopaed Res, NL-6522 JV Nijmegen, Netherlands
[3] Sint Maartensklin, Dept Anaesthesiol, NL-6522 JV Nijmegen, Netherlands
关键词
intraoperative monitoring; motor-evoked potentials; spinal surgery; TCE-MEP;
D O I
10.1097/00007632-200305150-00017
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A descriptive historic cohort study was conducted. Objectives. To determine intraoperative response amplitude criteria for transcranial electrical motor-evoked potential monitoring that warn of neurologic damage, and to determine the additional value of monitoring six instead of two muscle sites. Summary of Background Data. Transcranial electrical motor-evoked potential monitoring provides immediate and reliable information about the integrity of the motor pathways during spine surgery. Although this monitoring technique is more frequently used, criteria for interpretation of the amplitude responses have not been defined. Methods. The intraoperative monitoring outcomes were compared with the patient's clinical outcomes. The sensitivity, specificity, positive predictive value, and negative predictive value were determined for four different monitoring criteria. Results. Transcranial electrical motor-evoked potential monitoring was possible 142 of 145 patients undergoing corrective surgery. In this study, 16 patients had a neurologic event, and 11 patients showed recovery of response amplitude after a second surgical maneuver, whereas the remaining 5 patients had permanent partial neurologic damage. The criterion that at least one of six recordings must show an amplitude decrease of more than 80% was sufficiently strict to achieve a sensitivity of 1.0 and a specificity of 0.91. Less strict criteria, including recording at two instead of six sites, resulted in lower sensitivity, with the lower bound of the 95% confidence interval at 0.62. Conclusions. Transcranial electrical motor-evoked potential monitoring allowed successful intraoperative monitoring. The criterion of one recording showing a response amplitude decrease of more than 80% during a surgical action can be considered a valuable warning criterion for neurologic damage. The authors also consider that monitoring at six instead of two muscles improves the value of neuromonitoring.
引用
收藏
页码:1043 / 1050
页数:8
相关论文
共 21 条
[1]
ANTERIOR SPINAL-FUSION COMPLICATED BY PARAPLEGIA - A CASE-REPORT OF A FALSE-NEGATIVE SOMATOSENSORY-EVOKED POTENTIAL [J].
BENDAVID, B ;
HALLER, G ;
TAYLOR, P .
SPINE, 1987, 12 (06) :536-539
[2]
Threshold-level multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring [J].
Calancie, B ;
Harris, W ;
Broton, JG ;
Alexeeva, N ;
Green, BA .
JOURNAL OF NEUROSURGERY, 1998, 88 (03) :457-470
[3]
DAWSON EG, 1991, SPINE, V16, pS361
[4]
Somatosensory evoked potential monitoring in anterior thoracic vertebrectomy [J].
Deutsch, H ;
Arginteanu, M ;
Manhart, K ;
Perin, N ;
Camins, M ;
Moore, F ;
Steinberger, AA ;
Weisz, DJ .
JOURNAL OF NEUROSURGERY, 2000, 92 (02) :155-161
[5]
NONINVASIVE INTRAOPERATIVE MONITORING OF MOTOR EVOKED-POTENTIALS UNDER PROPOFOL ANESTHESIA - EFFECTS OF SPINAL SURGERY ON THE AMPLITUDE AND LATENCY OF MOTOR EVOKED-POTENTIALS [J].
JELLINEK, D ;
JEWKES, D ;
SYMON, L .
NEUROSURGERY, 1991, 29 (04) :551-557
[6]
Jones SJ, 1996, EVOKED POTENTIAL, V100, P375
[7]
VARIABILITY OF SOMATOSENSORY CORTICAL EVOKED-POTENTIALS DURING SPINAL SURGERY - EFFECTS OF ANESTHETIC TECHNIQUE AND HIGH-PASS DIGITAL FILTERING [J].
KALKMAN, CJ ;
TENBRINK, SA ;
BEEN, HD ;
BOVILL, JG .
SPINE, 1991, 16 (08) :924-929
[8]
KEITH RW, 1990, J SPINAL DISORD, V3, P220
[9]
Myogenic motor-evoked potential monitoring using partial neuromuscular blockade in surgery of the spine [J].
Lang, EW ;
Beutler, AS ;
Chesnut, RM ;
Patel, PM ;
Kennelly, NA ;
Kalkman, CJ ;
Drummond, JC ;
Garfin, SR .
SPINE, 1996, 21 (14) :1676-1686
[10]
A new application of TCE-MEP:: Spinal cord monitoring in patients with severe neuromuscular weakness undergoing corrective spine surgery [J].
Langeloo, DD ;
Journée, HL ;
Polak, B ;
de Kleuver, M .
JOURNAL OF SPINAL DISORDERS, 2001, 14 (05) :445-448