Efficiency enhancements in micellar liquid chromatography through selection of stationary phase and alcohol modifier

被引:22
作者
Thomas, David P.
Foley, Joe P.
机构
[1] Drexel Univ, Dept Chem, Philadelphia, PA 19104 USA
[2] McNeil Pharmaceut Inc, Analyt Tech Support, GPSG, Titusville, NJ 08560 USA
关键词
micellar liquid chromatography; MLC; chromatographic efficiency; reduced parameter plots; large-pore columns; perfluorinated stationary phase; column temperature effects on efficiency; diffusion coefficient; Taylor-Aris;
D O I
10.1016/j.chroma.2007.03.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Micellar liquid chromatography (MLC) remains hindered by reduced chromatographic efficiency compared to reversed phase liquid chromatography (RPLC) using hydro-organic mobile phases. The reduced efficiency has been partially explained by the adsorption of surfactant monomers onto the stationary phase, resulting in a slow mass transfer of the analyte within the interfacial region of the mobile phase and stationary phase. Using an array of 12 columns, the effects of various bonded stationary phases and silica pore sizes, including large-pore short alkyl chain, nonporous, superficially porous and perfluorinated, were evaluated to determine their impact on efficiency in MLC. Additionally, each stationary phase was evaluated using 1-propanol and 1-butanol as separate micellar mobile phase alcohol additives, with several columns also evaluated using 1-pentanol. A simplified equation for calculation of A' and C' terms from reduced plate height (h) versus reduced velocity (v) plots was used to compare the efficiency data obtained with the different columns and mobile phases. Analyte diffusion coefficients needed for the h versus v plots were Micellar liquid chromatography (MLC) remains hindered by reduced chromatographic efficiency compared to reversed phase liquid chromatography (RPLC) using hydro-organic mobile phases. The reduced efficiency has been partially explained by the adsorption of surfactant monomers onto the stationary phase, resulting in a slow mass transfer of the analyte within the interfacial region of the mobile phase and stationary phase. Using an array of 12 columns, the effects of various bonded stationary phases and silica pore sizes, including large-pore short alkyl chain, nonporous, superficially porous and perfluorinated, were evaluated to determine their impact on efficiency in MLC. Additionally, each stationary phase was evaluated using 1-propanol and 1-butanol as separate micellar mobile phase alcohol additives, with several columns also evaluated using 1-pentanol. A simplified equation for calculation of A' and C' terms from reduced plate height (h) versus reduced velocity (v) plots was used to compare the efficiency data obtained with the different columns and mobile phases. Analyte diffusion coefficients needed for the h versus v plots weredetermined by the Taylor-Aris dispersion technique. The use of a short alkyl chain, wide-pore silica column, specifically, Nucleosil C4, 1000 angstrom, was shown to have the most improved efficiency when using a micellar mobile phase compared to a hydro-organic mobile phase for all columns evaluated. The use of 1-propanol was also shown to provide improved efficiency over 1-butanol or 1-pentanol in most cases. In a second series of experiments, column temperatures were varied from 40 to 70 degrees C to determine the effect of temperature on efficiency for a subset of the stationary phases. Efficiency improvements ranging from 9% for a Chromegabond C8 column to 58% for a Zorbax ODS column were observed over the temperature range. Based on these observed improvements, higher column temperatures may often yield significant gains in column efficiency, assuming the column is thermally stable. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:282 / 293
页数:12
相关论文
共 53 条
[1]   ON THE DISPERSION OF A SOLUTE BY DIFFUSION, CONVECTION AND EXCHANGE BETWEEN PHASES [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1959, 252 (1271) :538-550
[2]   ON THE DISPERSION OF A SOLUTE IN A FLUID FLOWING THROUGH A TUBE [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 235 (1200) :67-77
[3]   USE OF AN AQUEOUS MICELLAR MOBILE PHASE FOR SEPARATION OF PHENOLS AND POLYNUCLEAR AROMATIC-HYDROCARBONS VIA HPLC [J].
ARMSTRONG, DW ;
HENRY, SJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (05) :657-662
[4]   MASS-TRANSFER IN THE MOBILE AND STATIONARY PHASES IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
BAILEY, R ;
CASSIDY, RM .
ANALYTICAL CHEMISTRY, 1992, 64 (19) :2277-2282
[5]   MICELLAR LIQUID-CHROMATOGRAPHY - RETENTION STUDY OF SOLUTES OF VARIOUS POLARITIES [J].
BERTHOD, A ;
GIRARD, I ;
GONNET, C .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1359-1362
[6]   ADDITIVE EFFECTS ON SURFACTANT ADSORPTION AND IONIC SOLUTE RETENTION IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
BERTHOD, A ;
GIRARD, I ;
GONNET, C .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1362-1367
[7]   MICELLAR LIQUID-CHROMATOGRAPHY - ADSORPTION-ISOTHERMS OF 2 IONIC SURFACTANTS ON 5 STATIONARY PHASES [J].
BERTHOD, A ;
GIRARD, I ;
GONNET, C .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1356-1358
[8]   INVESTIGATION OF THE CAUSES OF REDUCED EFFICIENCY IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
BERTHOD, A ;
BORGERDING, MF ;
HINZE, WL .
JOURNAL OF CHROMATOGRAPHY, 1991, 556 (1-2) :263-275
[9]   THE ROLE OF THE STATIONARY PHASE IN MICELLAR LIQUID-CHROMATOGRAPHY - ADSORPTION AND EFFICIENCY [J].
BERTHOD, A ;
ROUSSEL, A .
JOURNAL OF CHROMATOGRAPHY, 1988, 449 (02) :349-360
[10]   Causes and remediation of reduced efficiency in micellar liquid chromatography [J].
Berthod, A .
JOURNAL OF CHROMATOGRAPHY A, 1997, 780 (1-2) :191-206