Results of reoperation for hip dislocation - The big picture

被引:16
作者
Morrey, BF [1 ]
机构
[1] Mayo Clin, Rochester, MN 55906 USA
关键词
D O I
10.1097/01.blo.0000150318.27723.8c
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hip instability remains a costly complication of primary (3%) and revision (10%) procedures. In those with well-oriented components, instability may be anticipated in about 70% from advancement of the trochanter. Articular reorientation readily is affected by the use of modular cups with elevated rims. This has proven to be an effective strategy both to lessen the likelihood of an initial dislocation after both primary and revision procedures. It has also proven to be an effective strategy to treat the unstable implant, especially if cup orientation has been defined as the primary problem. Larger head sizes in the range of low-friction arthroplasty, such as 32 rum, are not any more stable than 22-mm diameter implants. Anatomic-sized heads as used in bipolar devices are effective in treating established instability in up to 90% of instances. The most popular current option is that of the constrained head/cup articulation. Good short-term results have revealed success in more than 90%. However, the effectiveness is design dependent, and the long-term effectiveness understandably is questioned as reports of mechanical failure begin to emerge.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 30 条
[1]
Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[2]
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[3]
Attarian D E, 1999, J South Orthop Assoc, V8, P249
[4]
The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[5]
Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement [J].
Beaule, PE ;
Schmalzried, TP ;
Udomkiat, P ;
Amstutz, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :256-263
[6]
The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :9-14
[7]
Use of constrained acetabular components for hip instability: An average 10-year follow-up study [J].
Bremner, BRB ;
Goetz, DD ;
Callaghan, JJ ;
Capello, WN ;
Johnston, RC .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :131-137
[8]
The elevated-rim acetabular liner in total hip arthroplasty: Relationship to postoperative dislocation [J].
Cobb, TK ;
Morrey, BF ;
Ilstrup, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (01) :80-86
[9]
OPERATIVE CORRECTION OF AN UNSTABLE TOTAL HIP-ARTHROPLASTY [J].
DALY, PJ ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (09) :1334-1343
[10]
Success rate of modular component exchange for the treatment of an unstable total hip arthroplasty [J].
Earll, MD ;
Fehring, TK ;
Griffin, WL ;
Mason, JB ;
McCoy, T ;
Odum, S .
JOURNAL OF ARTHROPLASTY, 2002, 17 (07) :864-869