Validation, using a chemometric approach, of gas chromatography-inductively coupled plasma-atomic emission spectrometry (GC-ICP-AES) for organotin determination

被引:15
作者
Aguerre, S [1 ]
Pécheyran, C [1 ]
Lespes, G [1 ]
机构
[1] Univ Pau & Pays Adour, CNRS, Lab Chim Analyt Bioinorgan & Environm, LCABIE,UMR 5034, F-64012 Pau, France
关键词
GC; ICP-AES; experimental design; organotin; speciation;
D O I
10.1007/s00216-003-1898-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The coupling between gas chromatography (GC) an. d inductively coupled plasma-atomic emission spectrometry (ICP-AES) has been optimised using experimental designs. Four factors were considered in order to assist the crucial part of the coupling which is the analytes passing through the transfer line. The methodological approach based on the planning of fractional designs is described and justified according to an optimal experimentation. Then, the GC-ICP-AES-based method has been validated by means of statistical tests performed on calibration curves and evaluation of accuracy, precision and limits of detection (LOD), according to ISO standards and IUPAC recommendations. The absolute LOD are found to be quite similar to those obtained using flame photometer. Relative LOD ranged between 20 and 80 ng (Sn) L-1 after liquid-liquid extraction of the analytes. When solid phase micro-extraction (SPME) is used, LOD are sub 10 ng (Sn)L-1. The repeatability is 3-10%, according to the extraction used. Analyses of reference sediment, fresh and waste waters confirm the suitability and capabilities of GC-ICP-AES for organotin determination in the environment. The statistical approach has been demonstrated to be a powerful methodological tool, enhancing the experimental part by providing reliable analytical results.
引用
收藏
页码:226 / 235
页数:10
相关论文
共 34 条
[1]   Speciation of organotins in environmental samples by SPME-GC: comparison of four specific detectors: FPD, PFPD, MIP-AES and ICP-MS [J].
Aguerre, S ;
Lespes, G ;
Desauziers, V ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :263-269
[2]   Optimisation of the hyphenation between solid-phase microextraction, capillary gas chromatography and inductively coupled plasma atomic emission spectrometry for the routine speciation of organotin compounds in the environment [J].
Aguerre, S ;
Pécheyran, C ;
Lespes, G ;
Krupp, E ;
Donard, OFX ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1429-1433
[3]   Solid phase microextraction (SPME): a new procedure for the control of butyl- and phenyltin pollution in the environment by GC-FPD [J].
Aguerre, S ;
Bancon-Montigny, C ;
Lespes, G ;
Potin-Gautier, M .
ANALYST, 2000, 125 (02) :263-268
[4]  
AGUERRE S, 2003, J CHROMATOGR A
[5]  
[Anonymous], 1988, METHODE PLANS EXPERI
[6]   Optimisation of the storage of natural freshwaters before organotin speciation [J].
Bancon-Montigny, C ;
Lespes, G ;
Potin-Gautier, M .
WATER RESEARCH, 2001, 35 (01) :224-232
[7]   Improved routine speciation of organotin compounds in environmental samples by pulsed flame photometric detection [J].
Bancon-Montigny, C ;
Lespes, G ;
Potin-Gautier, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :149-158
[8]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[9]  
CarlierPinasseau C, 1996, APPL ORGANOMET CHEM, V10, P505, DOI 10.1002/(SICI)1099-0739(199609)10:7<505::AID-AOC508>3.0.CO
[10]  
2-T