Assessment of physiologic variables and subjective comfort under different levels of pressure support ventilation

被引:84
作者
Vitacca, M
Bianchi, L
Zanotti, E
Vianello, A
Barbano, L
Porta, R
Clini, E
机构
[1] IRCCS, S Maugeri Fdn, Lung Funct Unit, I-25064 Brescia, Italy
[2] IRCCS, S Maugeri Fdn, Resp Intermediate Intens Care Unit, I-25064 Brescia, Italy
[3] Osped Civile, Fdn ONLUS Villa Pineta, Modena, Italy
[4] Univ Modena, I-41100 Modena, Italy
关键词
COPD; mechanical ventilation; symptoms; weaning;
D O I
10.1378/chest.126.3.851
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: To evaluate the effects of 12 ventilator settings (pressure support ventilation [PSV] plus positive end-expiratory pressure [PEEP], 30 + 0 cm H2O; 25 + 5 cm H2O; 25 + 0 cm H2O; 20 + 5 cm H2O; 20 + 0 cm H2O; 15 + 5 cm H2O; 15 + 0 cm H2O; 10 + 5 cm H2O; 10 + 0 cm H2O; 5 + 5 cm H2O; 5 + 0 cm H2O; and 0 + 5 cm H2O) on physiologic variables; the percentage of ineffective efforts; patient comfort; and whether the diagnosis of COPD may influence results. Design: Prospective, randomized, physiologic study. Setting: Three weaning centers. Patients: Thirty-six consecutive patients (20 patients with COPD). Intervention: Patients were randomly submitted to the 12 settings. Measurements and results: Breathing pattern, respiratory drive (p0.1), arterial oxygen saturation (Sato(2)), heart rate, percentage of ineffective efforts per minute, patient comfort measured by means of a visual analogue scale (VAS), and BORG scale were recorded under each setting. Under different levels of assistance, breathing pattern, Sato(2), and p0.1 significantly and linearly changed (p < 0.0001) while VAS and BORG scale presented a significant (p = 0.027) U-shaped trend; high or low assistance caused the most discomfort. Under high levels of assistance, a higher (analysis of variance, p = 0.023) frequency of ineffective effort percentage was observed in the subgroup of 26 patients who presented this phenomenon. Breathing pattern significantly (p = 0.013) changed when compared to PSV alone (PSV plus zero end-expiratory pressure [ZEEP]) at the same total inspiratory pressure assistance (PSV plus PEEP). A huge variability among patients in breathing pattern and comfort was found under the setting rated as the most comfortable by patients. The diagnosis of COPD did not influence the overall results. Conclusions: The following conclusions are made: (1) physiologic variables followed a linear trend, while comfort followed a U-shaped trend under different levels of PSV (irrespective of COPD diagnosis); (2) high assistance caused an increase in ineffective efforts; (3) only the breathing pattern significantly changed when total assistance was given as PSV plus PEEP when compared to PSV alone (PSV plus ZEEP); and (4) the extreme levels of PSV are not associated with the best comfort.
引用
收藏
页码:851 / 859
页数:9
相关论文
共 31 条
[1]   MEASUREMENT OF FEELINGS USING VISUAL ANALOGUE SCALES [J].
AITKEN, RCB .
PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1969, 62 (10) :989-+
[2]   P0.1 IS A USEFUL PARAMETER IN SETTING THE LEVEL OF PRESSURE SUPPORT VENTILATION [J].
ALBERTI, A ;
GALLO, F ;
FONGARO, A ;
VALENTI, S ;
ROSSI, A .
INTENSIVE CARE MEDICINE, 1995, 21 (07) :547-553
[3]   Mechanism of relief of tachypnea during pressure support ventilation [J].
Berger, KI ;
Sorkin, IB ;
Norman, RG ;
Rapoport, DM ;
Goldring, RM .
CHEST, 1996, 109 (05) :1320-1327
[4]   PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION [J].
BORG, GAV .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) :377-381
[5]   INSPIRATORY PRESSURE SUPPORT PREVENTS DIAPHRAGMATIC FATIGUE DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
HARF, A ;
LORINO, H ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (02) :513-521
[6]   COMPARISON OF 3 METHODS OF GRADUAL WITHDRAWAL FROM VENTILATORY SUPPORT DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
RAUSS, A ;
BENITO, S ;
CONTI, G ;
MANCEBO, J ;
REKIK, N ;
GASPARETTO, A ;
LEMAIRE, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (04) :896-903
[7]  
BROCHARD L, 1994, PRINCIPLES PRACTICE, P239
[8]   The effects of pressurization rate on breathing pattern, work of breathing, gas exchange and patient comfort in pressure support ventilation [J].
Chiumello, D ;
Pelosi, P ;
Croci, M ;
Bigatello, LM ;
Gattinoni, L .
EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (01) :107-114
[9]   EFFECTS OF CHANGES IN LEVEL AND PATTERN OF BREATHING ON THE SENSATION OF DYSPNEA [J].
CHONAN, T ;
MULHOLLAND, MB ;
ALTOSE, MD ;
CHERNIACK, NS .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (04) :1290-1295
[10]   A pilot study exploring mood state and dyspnea in mechanically ventilated patients [J].
Connelly, B ;
Gunzerath, L ;
Knebel, A .
HEART & LUNG, 2000, 29 (03) :173-179