Reducing inhomogeneity artifacts in functional MRI of human brain activation - Thin sections vs gradient compensation

被引:76
作者
Merboldt, KD
Finsterbusch, J
Frahm, J [1 ]
机构
[1] Biomed NMR Forsch GmbH, D-37070 Gottingen, Germany
[2] Max Planck Inst Biophys Chem, D-37070 Gottingen, Germany
关键词
functional magnetic resonance imaging; hippocampus; human brain activation; susceptibility artifacts; visual stimulation;
D O I
10.1006/jmre.2000.2105
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We evaluated two methods for correcting inhomogeneity-induced signal losses in magnetic resonance gradient-echo imaging that either use gradient compensation or simply acquire thin sections. The strategies were tested in the human brain in terms of achievable quality of T2*-weighted images at the level of the hippocampus and of functional activation maps of the visual cortex. Experiments were performed at 2.0 T and based on single-shot echo-planar imaging at 2.0 x 2.0 mm(2) resolution, 4 mm section thickness, and 2.0 s temporal resolution. Gradient compensation involved a sequential 16-step variation of the refocusing lobe of the slice-selection gradient (TR/TE = 125/53 ms, flip angle 15 degrees), whereas thin sections divided the 4-mm target plane into either four 1-mm or eight 0.5-mm interleaved multislice acquisitions (TR/TE = 2000/54 ms, flip angle 70 degrees). Both approaches were capable of alleviating the inhomogeneity problem for structures in the base of the brain. When compared to standard 4-mm EPI, functional mapping in the visual cortex was partially compromised because of a lower signal-to-noise ratio of inhomogeneity-corrected images by either method. Relative to each other, consistently better results were obtained with the use of contiguous thin sections, in particular for a thickness of 1 mm. Multislice acquisitions of thin sections require minimal technical adjustments. (C) 2000 Academic Press.
引用
收藏
页码:184 / 191
页数:8
相关论文
共 23 条
[1]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[2]  
Chen NK, 1999, MAGNET RESON MED, V42, P807, DOI 10.1002/(SICI)1522-2594(199910)42:4<807::AID-MRM25>3.0.CO
[3]  
2-8
[4]   REDUCTION OF SUSCEPTIBILITY ARTIFACT IN GRADIENT-ECHO IMAGING [J].
CHO, ZH ;
RO, YM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :193-200
[5]   Functional MR imaging using gradient-echo echo-planar imaging in the presence of large static field inhomogeneities [J].
Constable, RT .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06) :746-752
[6]  
CORDES D, 1998, P INT SOC MAGN RES M, P1446
[7]   THE INFLUENCE OF THE SLICE-SELECTION GRADIENT ON FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (01) :91-93
[8]   THE EFFECTS OF INTRAVOXEL DEPHASING AND INCOMPLETE SLICE REFOCUSING ON SUSCEPTIBILITY CONTRAST IN GRADIENT-ECHO MRI [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 109 (02) :234-237
[9]   DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480
[10]   FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION AT HIGH SPATIAL-RESOLUTION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :139-144