Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films

被引:109
作者
Palmisano, F [1 ]
Rizzi, R [1 ]
Centonze, D [1 ]
Zambonin, PG [1 ]
机构
[1] Univ Bari, Dipartmento Chim, I-70126 Bari, Italy
关键词
biosensors; glucose; lactate; multi-analyte sensing; permselective membranes; food;
D O I
10.1016/S0956-5663(00)00107-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An interference and cross-talk free dual electrode amperometric biosensor integrated with a microdialysis sampling system is described, for simultaneous monitoring of glucose and lactate by flow injection analysis. The biosensor is based on a conventional thin layer how-through cell equipped with a Pt dual electrode (parallel configuration). Each Pt disk was modified by a composite bilayer consisting of an electrosynthesised overoxidized polypyrrole (PPYox) anti-interference membrane covered by an enzyme entrapping gel, obtained by glutaraldehyde co-crosslinking of glucose oxidase or lactate oxidase with bovine serum albumin. The advantages of covalent immobilization techniques were coupled with the excellent interference-rejection capabilities of PPYox. Ascorbate, cysteine, urate and paracetamol produced lactate or glucose bias in the low micromolar range; their responses were, however, completely suppressed when the sample was injected through the microdialysis unit. Under these operational conditions the flow injection responses for glucose and lactate were linear up to 100 and 20 mM with typical sensitivities of 9.9 (+/- 0.1) and 7.2 (+/- 0.1) nA/mhil, respectively. The shelf-lifetime of the biosensor was at least 2 months. The potential of the described biosensor was demonstrated by the simultaneous determination of lactate and glucose in untreated tomato juice samples; results were in good agreement with those of a reference method. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:531 / 539
页数:9
相关论文
共 34 条
[1]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[2]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[3]  
BILITEWSKI U, 1992, P TRENDS EL BIOS SIN, P59
[4]  
BROOKS SL, 1987, BIOSENSORS, V3, P45
[5]   BIOSENSORS FOR PROCESS-CONTROL [J].
BROOKS, SL ;
HIGGINS, IJ ;
NEWMAN, JD ;
TURNER, APF .
ENZYME AND MICROBIAL TECHNOLOGY, 1991, 13 (12) :946-955
[6]   INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM [J].
CENTONZE, D ;
GUERRIERI, A ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09) :729-733
[7]  
Centonze D, 1997, J AOAC INT, V80, P829
[8]  
CENTONZE D, 1992, ANN CHIM-ROME, V82, P219
[9]   ELECTROANALYTICAL X-RAY PHOTOELECTRON-SPECTROSCOPY INVESTIGATION ON GLUCOSE-OXIDASE ADSORBED ON PLATINUM [J].
DEBENEDETTO, GE ;
MALITESTA, C ;
ZAMBONIN, CG .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (11) :1495-1499
[10]  
Dempsey E, 1997, ANAL CHIM ACTA, V346, P341