Application of a particle separation device to reduce inductively coupled plasma-enhanced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry

被引:98
作者
Guillong, M [1 ]
Kuhn, HR [1 ]
Günther, D [1 ]
机构
[1] Swiss Fed Inst Technol, Inorgan Chem Lab, CH-8093 Zurich, Switzerland
关键词
particle size; laser ablation; aerosol; fractionation;
D O I
10.1016/S0584-8547(02)00257-4
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The particle size distribution of laser ablation aerosols are a function of the wavelength, the energy density and the pulse duration of the laser, as well as the sample matrix and the gas environment. Further the size of the particles affects the vaporization and ionization efficiency in the inductively coupled plasma (ICP). Some matrices produce large particles, which are not completely vaporized and ionized in the ICP The previous work has shown that analytical results such as matrix-independent calibration, accuracy and precision can be significantly influenced by the particle sizes of the particles. To minimize the particle size related incomplete conversion of the sample to ions in the ICP a particle separation device was developed, which allows effective particle separation using centrifugal forces in a thin coiled tube. In this device, the particle cut-off size is varied by changing the number of turns in the coil, as well as by changing the gas flow and the tube diameter. The interaction of the laser with the different samples leads to varying particle size distributions. When carrying out quantitative analysis with non-matrix matched calibration reference materials, it was shown that different particle cut-off sizes were required depending on the ICP conditions and the instrument used for analysis. Various sample materials were investigated in this study to demonstrate the applicability of the device. For silicate matrices, the capability of the ICP to produce ions was significantly reduced for particles larger than 0.5 mu.m, and was dependent on the element monitored. To reduce memory effects caused by the separated particles, a washout procedure was developed, which additionally allowed the analysis of the trapped particles. These results clearly demonstrate the very important particle size dependent ICP-MS signal response and the potential of the described particle size based separator for the reduction of ICP induced elemental fractionation. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 16 条
[1]  
Durrant SF, 2000, J ANAL ATOM SPECTROM, V15, P237
[2]   More investigations into elemental fractionation resulting from laser ablation inductively coupled plasma mass spectrometry on glass samples [J].
Figg, DJ ;
Cross, JB ;
Brink, C .
APPLIED SURFACE SCIENCE, 1998, 127 :287-291
[3]   Effect of particle size distribution on ICP-induced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry [J].
Guillong, M ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :831-837
[4]   Capabilities of a homogenized 266 nm Nd:YAG laser ablation system for LA-ICP-MS [J].
Guillong, M ;
Horn, I ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (01) :8-14
[5]   Wavelength dependant ablation rates for metals and silicate glasses using homogenized laser beam profiles -: implications for LA-ICP-MS [J].
Horn, I ;
Guillong, M ;
Günther, D .
APPLIED SURFACE SCIENCE, 2001, 182 (1-2) :91-102
[6]  
HORN I, IN PRESS APPL SURF S
[7]   Effects of particle size distribution on inductively coupled plasma mass spectrometry signal intensity during laser ablation of glass samples [J].
Jeong, SH ;
Borisov, OV ;
Yoo, JH ;
Mao, XL ;
Russo, RE .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5123-5130
[8]   Elemental composition of laser ablation aerosol particles deposited in the transport tube to an ICP [J].
Koch, J ;
Feldmann, I ;
Jakubowski, N ;
Niemax, K .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (05) :975-985
[9]   A critical assessment of laser ablation ICP-MS as an analytical tool for depth analysis in silica-based glass samples [J].
Mank, AJG ;
Mason, PRD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1143-1153
[10]   Development of a cyclone separator with new design [J].
Molerus, O ;
Gluckler, M .
POWDER TECHNOLOGY, 1996, 86 (01) :37-40