Computer-aided diagnosis for 3-dimensional breast ultrasonography

被引:26
作者
Chen, DR
Chang, RF
Chen, WM
Moon, WK
机构
[1] China Med Coll & Hosp, Dept Gen Surg, Taichung, Taiwan
[2] Natl Chung Cheng Univ, Dept Comp Sci & Informat Engn, Chiayi, Taiwan
[3] Seoul Natl Univ Hosp, Dept Diagnost Radiol, Seoul 110744, South Korea
关键词
D O I
10.1001/archsurg.138.3.296
中图分类号
R61 [外科手术学];
学科分类号
摘要
Hypothesis: Using 3-dimensional (3-D) over 2-dimensional (2-D) ultrasonographic (US) images of the breast represents a potentially significant advantage for computer-aided diagnosis (CAD). Background: Although conventional 2-D US images of the breast are increasingly used in surgical, clinical practice, 3-D US imaging of the breast, a newly introduced technique, can offer more information than 2-D US images do. Design: This study deals with a I CAD method for use with the proposed 3-D US images of the breast and compares its performance with conventional 2-D US versions. Methods: The test databases included 3-D US images of 107 benign and 54 malignant breast tumors for a total of 161 US images. All solid nodules at US belong to categories above C3 (ie, probably benign). The 3-D US imaging was performed using a scanner (Voluson 530; kretz Technik, Zipf, Austria). New 3-D autocorrelation coefficients extended from the traditional 2-D autocorrelations were developed to extract the texture characteristics of the 3-D US images. The extracted texture features of the 3-D US images were used to classify the tumor as benign or malignant using the neural network. Results: At the receiver operating characteristic analysis, 3-D and 2-D autocorrelation calculating schemes yielded Az values (ie, area under the receiver operating characteristic curve) of 0.97 and 0.85 in distinguishing between benign and malignant lesions, respectively. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value are statistically significantly improved using 3-D instead of 2-D US images for CAD. Conclusions: The proposed system (for 3-D and 2-D CAD) is expected. to be a useful computer-aided diagnostic tool for classifying benign and malignant tumors on ultrasonograms and can provide a second reading to help reduce misdiagnosis. Findings from this study suggest that using 3-D over 2-D US images for CAD represents a potentially significant advantage.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 15 条
[1]   Breast cancer diagnosis using self-organizing map for sonography [J].
Chen, DR ;
Chang, RF ;
Huang, YL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :405-411
[2]   Computer-aided diagnosis applied to US of solid breast nodules by using neural networks [J].
Chen, DR ;
Chang, RF ;
Huang, YL .
RADIOLOGY, 1999, 213 (02) :407-412
[3]   Texture analysis of breast tumors on sonograms [J].
Chen, DR ;
Chang, RF ;
Huang, YL ;
Chou, YH ;
Tiu, CM ;
Tsai, PP .
SEMINARS IN ULTRASOUND CT AND MRI, 2000, 21 (04) :308-316
[4]  
CHENG XY, 1997, P ICIP 97 IEEE INT C, V3, P420
[5]  
Cristianini N, 2000, Intelligent Data Analysis: An Introduction
[6]  
FENSTER A, 1998, P IEEE INSTR MEAS TE, V1, P562
[7]   IMPROVING THE DISTINCTION BETWEEN BENIGN AND MALIGNANT BREAST-LESIONS - THE VALUE OF SONOGRAPHIC TEXTURE ANALYSIS [J].
GARRA, BS ;
KRASNER, BH ;
HORII, SC ;
ASCHER, S ;
MUN, SK ;
ZEMAN, RK .
ULTRASONIC IMAGING, 1993, 15 (04) :267-285
[8]   Computerized analysis of lesions in US images of the breast [J].
Giger, ML ;
Al-Hallaq, H ;
Huo, ZM ;
Moran, C ;
Wolverton, DE ;
Chan, CW ;
Zhong, WM .
ACADEMIC RADIOLOGY, 1999, 6 (11) :665-674
[9]  
GONZALEZ RC, 1992, DIGITAL IMAGE PROCES, P312
[10]  
HENG XY, 1997, P 19 INT C IEEE ENG, P517